TandD

7 Items

Set Descending Direction
per page
  1. Indoor Carbon Dioxide Data Logger
    TR-76Ui
    • Measures and Records Carbon Dioxide (CO2), Temperature and Humidity in Indoor Environments
    • 0 to 5,000 ppm (CO2), 0°C to 45°C (Temp) and 10 to 90% RH (Humidity) Measurement Ranges
    • Programmable Alarms and Contact Closure Output
    • Large LCD Display will Cycle Through all Three Measurements
    • Perfect for Air Quality Monitoring and IAQ Auditing

    Includes Sensors, Software, (4) AA Alikaline Batteries, USB Cable and AC Adapter

  2. Barometric Pressure, Humidity and Temperature Data Logger
    TR-73U
    • Easy-to-Use USB Computer Connection (Multiple Data Loggers Can Be Connected)
    • Simultaneous Monitoring of Multiple Channels of Data Through Software
    • 24,000 Total Readings (8,000 per Channel)
    • Up to One Year of Battery Life with Continued Usage (Dependent on Sampling Rate)
    • High Speed Data Transfer Downloads 8,000 Readings in About 8 Seconds

    Includes TR-3100 Sensor, Software Manual and CD, USB Cable, and AA Alkaline Battery

  3. Wireless Carbon Dioxide, Humidity and Temperature Data Logger
    RTR-576
    • Simultaneously Measure and Record Carbon Dioxide, Humidity and Temperature Readings
    • Measurement Range of 0 to 9,999ppm (CO2); 10% to 95% RH (Humidity) and 0°C to 55°C (Temp)
    • Stores 8,000 Data Samples Between Wireless Transmissions to Base Collector or Repeater
    • 150 Meters Line of Sight Transmission Range Between Devices (Logger to Base Collector or Repeaters)
    • Automatic Transmission of Data (Current or Logged) at Set Interval to Base Collector or Repeater

    Includes Logger, (4) AA Alkaline Battery, External Temp/RH Sensor, AC Adapter, USB Cable and User Manual

    A Complete System Requires a Base Collector (RTR-500DC, RTR-500GSM, RTR-500NW or RTR-500AW) and a RTR-500 Series Wireless Data Logger

  4. RTR-574 Illuminance, UV, Temp & Humidity Data Logger
    RTR-574
    • Simultaneously Measure and Record Illuminance, Ultraviolet (UV), Temp and Humidity
    • Stores 8,000 Data Samples Between Wireless Transmissions to Base Collector or Repeater
    • 150 Meters Line of Sight Transmission Range Between Devices (Logger to Base Collector or Repeaters)
    • Automatic Transmission of Data (Current or Logged) at Set Interval to Base Collector or Repeater
    • View Current Readings, Cumulative Illuminance and Cumulative Amount of UV Light on 4 Digit LCD Display

    Includes Logger, AA Alkaline Battery, USB Cable, PC Software, User Manual and Sensors w/ 10 Meter Cable

    A Complete System Requires a Base Collector (RTR-500DC, RTR-500MBS-A, RTR-500NW or RTR-500AW) and a RTR-500 Series Wireless Data Logger

  5. RTR-574-S Illuminance, UV, Temp & Humidity Data Logger
    RTR-574-S
    • Simultaneously Measure and Record Illuminance, Ultraviolet (UV), Temp and Humidity 
    • Stores 8,000 Data Samples Between Wireless Transmissions to Base Collector or Repeater
    • 150 Meters Line of Sight Transmission Range Between Devices (Logger to Base Collector or Repeaters)
    • Automatic Transmission of Data (Current or Logged) at Set Interval to Base Collector or Repeater
    • View Current Readings, Cumulative Illuminance and Cumulative Amount of UV Light on 4 Digit LCD Display

    Includes Logger, AA Alkaline Battery, USB Cable, PC Software, User Manual and Sensors w/ 10 Meter Cable

    A Complete System Requires a Base Collector (RTR-500DC, RTR-500MBS-A, RTR-500NW or RTR-500AW) and a RTR-500 Series Wireless Data Logger

  6. Wireless High Precision Carbon Dioxide, Humidity and Temperature Data Logger
    RTR-576-S
    • Simultaneously Measure and Record Carbon Dioxide, Humidity and Temperature Readings
    • Measurement Range of 0 to 9,999ppm (CO2); 0% to 99% RH (Humidity) and -25°C to 70°C (Temp)
    • Stores 8,000 Data Samples Between Wireless Transmissions to Base Collector or Repeater
    • 150 Meters Line of Sight Transmission Range Between Devices (Logger to Base Collector or Repeaters)
    • Automatic Transmission of Data (Current or Logged) at Set Interval to Base Collector or Repeater

    Includes Logger, (4) AA Alkaline Battery, External Temp/RH Sensor, AC Adapter, USB Cable and User Manual

    A Complete System Requires a Base Collector (RTR-500DC, RTR-500GSM, RTR-500NW or RTR-500AW) and a RTR-500 Series Wireless Data Logger

    Wireless Notice and Disclaimer
    The use of Radio Frequency products is tightly regulated by local laws. Wireless products sold by MicroDAQ, LLC are approved for use in the U.S. and Canada, but may not be in other countries. It is the sole responsibility of our customers to insure that the local use of wireless products purchased on this site is in full compliance with all local laws and regulations. MicroDAQ, LLC and the manufacturers it represents will not accept any responsibility for the use of unapproved wireless product in other countries.

  7. Carbon Dioxide Data Logger with Wide Temperature and RH Range
    TR-76UI-S
    • Measures and Records Carbon Dioxide (CO2), Temperature and Humidity in Indoor Environments
    • 0 to 5,000 ppm (CO2), -25°C to 70°C (Temp) and 0 to 99% RH (Humidity) Measurement Ranges
    • Programmable Alarms and Contact Closure Output
    • Large LCD Display will Cycle Through all Three Measurements
    • Perfect for Air Quality Monitoring and IAQ Auditing

    Includes Sensors, Software, (4) AA Alkaline Batteries, USB Cable and AC Adapter

per page
Copyright © 2024 MicroDAQ, LLC. All Rights Reserved.