Acuvim-3 Advanced Power Quality Meter

SKU
ACUVIM-3-D-5A-P1
$3,500.00
  • Power Quality and Revenue Grade Energy Compliant to IEC 61000-4-30 Class A Standard
  • Measures Voltage, Current, Power (Reactive, Apparent, Active), Energy, Power Factor, Frequency and Run Time
  • Sampling Rate at 1024 Samples/Cycle
  • Multiple Communication Options: Ethernet, ModBus, BACnet and SNMP
  • Time Synchronization, 32GB Internal Memory and Optional 7" HMI Color Display
  • Accepts up to (1) I/O Modules (AXM-IO1, AXM-IO2 or AXM-IO3)
  • If a Communications Module (AXM-PROFI, AXM-WEB-PUSH or AXM-WEB2) is Attached, only (2) I/O Modules can be Added

AcuView Software for Remote Meter Access and Control, Real-Time Monitoring and Local PC Logging Available for Download

Contact Us for Pricing

This item is imported from Canada - All orders are Subject to a 35% Tariff

Built to order - please allow 7-10 business days for this item to ship from our warehouse
 

Overview of the Accuenergy ACUVIM-3 Power Meter

The ACUVIM-3 meter by Accuenergy is a cutting-edge power quality analyzer and revenue grade power meter. This advanced device is designed to ensure precise measurement of waveform, harmonics, frequency, voltage, and current at high resolution. With its certified IEC 61000-4-30 Class A compliance, the ACUVIM-3 guarantees accurate power quality monitoring for a wide range of applications.

The Accuenergy ACUVIM-3 meter boasts a high-speed sampling data rate, extensive data log storage capacity, event detection capabilities, and EN50160/IEEE519 compliant reporting. It also meets the stringent requirements of ANSI C12.20 Class 0.1 and IEC 62053-22 Class 0.1 standards, making it ideal for high-accuracy metering applications focused on energy optimization and management.

User Manuals and Product Guides
Product Videos

AccuEnergy Acuvim-3 Power Meter Specifications

Voltage Measurement Range (VLN): 10 Volts to 400 Volts
Measurement Range (VLL): 17.3 Volts to 690 Volts
Accuracy: 0.1%
Resolution: 0.001 Volts
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Current Measurement Range (1 Amp): 10mA to 2 Amps
Measurement Range (5 Amp): 50mA to 10 Amps
Measurement Range (333 mV): 3mV to 400 mV
Measurement Range (Rogowski Coil): 3mV to 400 mV
Accuracy: 0.1%
Resolution: 0.001 Amps
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Power Measurement Range: -999999.999MW to 999999.999MW
Accuracy: 0.1%
Resolution: 1 Watt
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Reactive Power Measurement Range: -999999.999Mvar to 999999.999Mvar
Accuracy: 0.1%
Resolution: 1 var
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Apparent Power Measurement Range: 0 to 999999.999MVA
Accuracy: 0.1%
Resolution: 1 VA
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Power Demand Measurement Range: -999999.999MW to 999999.999MW
Accuracy: 0.1%
Resolution: 1 Watt
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Reactive Power Demand Measurement Range: -999999.999Mvar to 999999.999Mvar
Accuracy: 0.1%
Resolution: 1 var
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Apparent Power Demand Measurement Range: 0 to 999999.999MVA
Accuracy: 0.1%
Resolution: 1 VA
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Power Factor Measurement Range: -1.000 to 1.000
Accuracy: 0.1%
Resolution: 0.001
Frequency Measurement Range: 40.0 Hz to 70.0 Hz
Accuracy: 0.001%
Resolution: 0.001 Hz
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle); 10s
Energy Measurement Range: 0 to 999999.999MWh
Accuracy: 0.1%
Resolution: 0.001 Wh
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Reactive Energy Measurement Range: 0 to 999999.999Mvarh
Accuracy: 0.1%
Resolution: 0.001 varh
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Apparent Energy Measurement Range: 0 to 999999.999MVAh
Accuracy: 0.1%
Resolution: 0.001VAh
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Harmonics Accuracy: 0.15%
Resolution: 0.001%
Update Rate: 200ms (10/12 Cycle)
Phase Angle Measurement Range: 0 to 359.999°
Resolution: 0.001°
Update Rate: 1/2 Cycle; 200ms (10/12 Cycle)
Unbalance Factor Measurement Range: 0 to 100.00%
Accuracy: 0.15%
Resolution: 0.001%
Update Rate: 200ms (10/12 Cycle)
Flicker Accuracy: 5.%
Short Term: 10 Minutes
Long Term: 2 Hour
Running Time 1 Minute
Current Inputs (Each Channel) Nominal Current Options: 5A, 1A, 333mV, Rogowski Coil
Metering Range: 0 to 10 Amps, 0 to 2 Amps, 0 to 400mV
Pickup Current: 0.5mA and 0.25mV
Withstand: 20Arms Continuous, 50Arms @ 10 sec/hr, 500Arms @ 1sec/hr
Burden: 0.05 VA (Typical) @ 5A RMS
Accuracy: 0.1% at Reading
Voltage Inputs (Each Channel) Nominal Full Scale: 400 Volts AC L-N,690 Volts AC L-L (-20%)
Withstand: 1500 Volts AC Continuous, 2500 Volts AC, 50/60Hz for 1 Minute
Input Impedance: 2MΩ per Phase
Metering Frequency: 40Hz to 70Hz
Pickup Voltage: 5 Volts AC
Accuracy: 0.1% at Reading
Digital Input Input Type: Dry
Input Resistance: 100kΩ
Input Voltage Range: 20 to 160 Volts AC/DC
Input Current: 2mA (Max)
Start Voltage: 15 Volts
Stop Voltage: 5 Volts
Pulse Frequency (Max): 100Hz, 50% Duty Ratio (5ms ON, 5ms OFF)
SOE Resolution: 2ms
Digital Output Voltage Range: 0 to 250 Volts AC/DC
Load Current: 100mA (Max)
Output Frequency: 25Hz, 50% Duty Ratio (20ms ON, 20ms OFF)
Isolation Voltage: 2500 Volts AC
Relay Output Switching Voltage: 250 Volts AC, 30 Volts DC (Max)
Load Current: 5 Amps (R), 2 Amps (L)
Set Time: 10ms (Max)
Contact Resistance: 30mΩ (Max)
Isolation Voltage: 2500 Volts AC
Analog Output Output Range: 0 to 5 Volts, 0 to 20 mA, 1 to 5 Volts, 4 to 20 mA
Accuracy: 0.50%
Temperature Drift: 50ppm/°C Typical
Isolation Voltage: 500 Volts DC
Open Circuit Voltage: 15 Volts
Analog Input Input Range: 0 to 5 Volts, 0 to 20 mA, 1 to 5 Volts, 4 to 20 mA
Accuracy: 0.20%
Temperature Drift: 50ppm/°C Typical
Isolation Voltage: 500 Volts DC
Communications Serial Port Protocols: Modbus-RTU (9600 to 115200 bps)
Web Server: HTTP/HTTPS
Time Synchronization: NTP, SNTP, IRIG-B, PTP
Ethernet: IPv4, IPv6, DNS, MODBUS-TCP/IP, DNP 3.0 over IP Level 2, IEC 61850 1st and 2nd Edition, PMU (C37.118), SNMP V2C and V3, BACnet-IP, HTTP/HTTPS Webserver File Download, HTTP/HTTPS, FTP, sFTP, SMTP Email Data Post, EtherNet/IP
WI-FI: 802.11 b/g/n 2.4 GHz/5 GHz
AC/DC Control Power Operating Range: AC(P1): 100 to 415 Volts AC, 50/60Hz, 100 to 300 Volts DC; DC(P2): 20 to 60 Volts DC ± 10%
Burden: 15 Watt, 25 Volt Amps
Frequency: 50/60 Hz
Withstand: 3250 Volts AC, 50/60 Hz for 1 Minute; Installation Category III (Distribution)
Operating Environment Temperature: -25°C to 70°C (-13°F to 158°F)
Humidity: 5% to 95% RH Non-Condensing
Altitude: <3000 Meters
Pollution Degree: 2
Location/Mountain: Indoor Use Only
Storage Environment Temperature: -40°C to 70°C (-40°F to 158°F)
Humidity: 5% to 95% RH Non-Condensing
Standards Compliance IP54 (Panel Mount and Touchscreen Display, Front), IP30 (Panel Mount Rear, DIN Rail Mount, I/O Modules, IEC62053-22, ANSI C12.20, IEC61557-12