SRP-004 SmartReader Plus 4 Pressure and Temperature Data Logger
ACR 01-0120 4 Channel Data Logger: Pressure, Temperature and 2 for optional RH/Temp Probes
SKU
01-0115
$1,331.00
- Measure and Record Pressure and Temperature and (2) Optional Inputs for Temp and RH
- Self-Contained with 1/4" Quick-Release Pressure Fitting Connection
- (7) Pressure Ranges Available with ±0.5% of Full Scale @ 25°C
- 25/second to 8 Hour User-Selectable Sampling Rate
- Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
- Continuous (FIFO) or Stop When Full Sampling Methods
Due to Increased Freight Costs, All ACR Systems Orders Must Have a Minimum Order Value of $100
Special order - please allow 6-8 weeks for this item to ship.
SRP-004 ACR Systems SmartReader Plus 4 (Cat#01-0115) Pressure Data Logger Specifications
Channels | (1) Pressure, (1) Temperature and (2) Optional Inputs for Temperature and/or Humidity |
Accuracy | ±0.5% of full scale @25°C (77°F) |
Pressure Sensor | Multiple Ranges Available: 1. 0 to 10" WC (2.5 kPa) Gauge @ 0.006" Resolution 2. 0 to 5 psi (30 kPa) Gauge @ 0.003 psi (0.02 kPa) Resolution 3. 0 to 30 psi (200 kPa) Absolute @ 0.015 psi (0.1 kPa) Resolution 4. 0 to 30 psi (200 kPa) Gauge @ 0.015 psi (0.1 kPa) Resolution 5. 0 to 100 psi (700 kPa) Absolute @ 0.05 psi (0.34 kPa) Resolution 6. 0 to 100 psi (700 kPa) Gauge @ 0.05 psi (0.34 kPa) Resolution 7. 0 to 150 psi (1000 kPa) Gauge @ 0.05 psi (0.34 kPa) Resolution |
Temperature Sensor | Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25°C (77°F) |
Temperature Accuracy | ± 0.2°C, over the range of 0 to 70°C (±0.3°F over the range of 32 to 158°F) |
Temperature Range | -40 to 70°C (-40 to 158°F) |
Temperature Resolution | 0.03°C (0.05°F) at 25°C (77°F). Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C (158°F). Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C (-13°F) |
Memory | 128KB (87,000 Readings) |
External Connector | Removable Screw-Type Terminal Strip with Common (-) Connection |
Operating Limits | -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing) |
Clock Accuracy | +/- 2 Seconds per Day |
Power Consumption | 5 to 10 microamps (continuous) |
Sampling Methods | Continuous: First-In, First Out (not available with Sample Rates faster than 8 seconds) Stop when Full: (Fill-then-Stop) |
Sampling Rates | User Selectable Rates from 25 per second to 1 Reading Every 8 Hours. Battery Pack (#BP-101) or Power Supply (#PS-201) required for sample Rates Faster than 8 second |
Resolution | 12 Bit (1 part in 4,096) |
Product Approvals | Meets Part 15 for Digital Devices of the Code of Federal Regualtions of the FCC Meets Radiated and Conducted Emission Requirements for the Interfernce Causing Equipment Standard for Digital Apparatus of Industry Canada (ICES-003). IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emissions respectively for the Commission of the European Communities (CE) |
Resistance to X-Rays | Tested for protection against a 160kV dose @ 5mA for 30 Seconds (150 mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport x-ray machine). Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192-28 curies @ 320 second exposure source to object distance 5" |
Battery | 3.6 Volt Lithium, 1 Amp-Hour |
Battery Life | 10 Year Warranty (under normal use), Factory Replaceable |
Case Material | Noryl Plastic |
Mounting | Magnetic Backing or Locking Eyelet |
Size | 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9") |
Weight | 110 grams (3.75 Ounces) |
OS Compatibility | Windows 11, 10 and 7 (32 and 64 Bit) |