  • Water Level Sensor for MX2001 Bluetooth Data Logger, MicroRX Water Level Stations (RX2103 and RX2104) and RX3000 Remote Monitoring Station
  • 0 to 30 ft Water Depth Range and 0.05% FS Typical Accuracy
  • Durable Ceramic Sensor and Non-Vented Design Reduces Maintenance
  • Titanium Housing

Includes Protective Cap

Special order - please note lead times for some items can take up to 8 weeks
 

HOBO™ MX2001-01-TI Water Level Sensor Specifications

Pressure (Absolute) and Water Level Measurements with MX2001-01-S or MX2001-01-Ti-S Operating Range (Sea Level): 0 to 207 kPa (0 to 30 psia, 0 to 9 Meters, 0 to 30 ft) of Water Depth
Operating Range (3,000 Meter Altitude): 0 to 207 kPa (0 to 30 psia, 0 to 12 Meters, 0 to 40 ft) of Water Depth
Factory Calibrated Range: 69 to 207 kPa (10 to 30 psia) @ 0°C to 40°C (32°F to 104°F)
Burst Pressure: 310 kPa (45 psia) or 18 Meters (60 ft) Depth
Water Level Accuracy (Typical): ±0.05% FS, 0.5cm (0.015 ft) Water
Water Level Accuracy (Maximum): ±0.1% FS, 1.0cm (0.03 ft) Water
Raw Pressure Accuracy: 0.3% FS, 0.62kPa (0.09 psi) Maximum Error
Resolution: <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) Water
Pressure Response Time***: <1 second at a Stable Temperature
* With Accurate Reference Water Level Measurement, Known Water Density, and a Stable Temperature Environment. System Water Level Accuracy Equals the Sum of the Barometric Water Level Accuracy plus the Selected Water Level Accuracy.
** Absolute Pressure Sensor Accuracy includes all Sensor Drift, Temperature and Hysteresis-induced Errors.
*** Changes in Temperature: Allow 20 Minutes in Water to Achieve Full Temperature Compensation of the Pressure Sensor. There Can Be Up To 0.5% of Additional Error Due to Rapid Temperature Changes. Measurement Accuracy Also Depends on Temperature Response Time.
Barometric Pressure Operating Range: 66 to 107 kPa (9.57 to 15.52 psia)
Temperature Calibrated Range: -20°C to 50°C (-4°F to 122°F)
Accuracy: ±0.2 kPa (±0.029 psi) Over Full Temperature Range at Fixed Pressure; Max Error: ±0.5% FS
Water Level Accuracy (Typical): ±0.075% FS, 0.3cm (0.01 ft) Water
Water Level Accuracy (Maximum): ±0.15% FS, 0.6cm (0.02 ft) Water
Resolution: <0.01 kPa (0.0015 psi)
Response Time: <1 second at a Stable Temperature
Drift (Stability): <0.01 kPa (0.0015 psi) per Year
Temperature Operating Range (Sea Level): -20°C to 50°C (-4°F to 122°F)
Accuracy: 0.44°C from 0°C to 50°C (0.79°F from 32°F to 122°F)
Resolution: 0.1°C at 25°C (0.18°F at 77°F)
Response Time (90%): 5 Minutes in Water (Typical)
Stability (Drift): 0.1°C (0.18°F) per Year