HOBO™ MX2001-03-SS-S Stainless Steel Water Level Sensor (0 to 250 ft)

SKU
MX2001-03-SS-S
Special Order
$449.00
  • Water Level Sensor for MX2001 Bluetooth Data Logger, MicroRX Water Level Stations (RX2103 and RX2104) and RX3000 Remote Monitoring Station
  • 0 to 250 ft Water Depth Range and 0.05% FS Typical Accuracy
  • Durable Ceramic Sensor and Non-Vented Design Reduces Maintenance
  • Stainless Steel Housing

Includes Protective Cap

Special order - please note lead times for some items can take up to 8 weeks
 

HOBO™ MX2001-03-SS-S Water Level Sensor Specifications

Pressure (Absolute) and Water Level Measurements with MX2001-03-S Operating Range (Sea Level): 0 to 850 kPa (0 to 123.3 psia, 0 to 76.5 Meters, 0 to 251 ft) of Water Depth
Operating Range (3,000 Meter Altitude): 0 to 850 kPa (0 to 123.3 psia, 0 to 79.5 Meters, 0 to 262 ft) of Water Depth
Factory Calibrated Range: 69 to 850kPa (10 to 123.3 psia) @ 0°C to 40°C (32°F to 104°F)
Burst Pressure: 500 kPa (72.5 psia) or 40.8 Meters (134 ft) Depth
Water Level Accuracy (Typical): ±0.05% FS, 1.5cm (0.05 ft) Water
Water Level Accuracy (Maximum): ±0.1% FS, 3.0cm (0.1 ft) Water
Raw Pressure Accuracy: 0.3% FS, 1.20 kPa (0.17 psi) Maximum Error
Resolution: <0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) Water
Pressure Response Time: <1 second at a Stable Temperature
* With Accurate Reference Water Level Measurement, Known Water Density, and a Stable Temperature Environment. System Water Level Accuracy Equals the Sum of the Barometric Water Level Accuracy plus the Selected Water Level Accuracy.
** Absolute Pressure Sensor Accuracy includes all Sensor Drift, Temperature and Hysteresis-induced Errors.
*** Changes in Temperature: Allow 20 Minutes in Water to Achieve Full Temperature Compensation of the Pressure Sensor. There Can Be Up To 0.5% of Additional Error Due to Rapid Temperature Changes. Measurement Accuracy Also Depends on Temperature Response Time.
Barometric Pressure Operating Range: 66 to 107 kPa (9.57 to 15.52 psia)
Temperature Calibrated Range: -20°C to 50°C (-4°F to 122°F)
Accuracy: ±0.2 kPa (±0.029 psi) Over Full Temperature Range at Fixed Pressure; Max Error: ±0.5% FS
Water Level Accuracy (Typical): ±0.075% FS, 0.3cm (0.01 ft) Water
Water Level Accuracy (Maximum): ±0.15% FS, 0.6cm (0.02 ft) Water
Resolution: <0.01 kPa (0.0015 psi)
Response Time: <1 second at a Stable Temperature
Drift (Stability): <0.01 kPa (0.0015 psi) per Year
Temperature Operating Range (Sea Level): -20°C to 50°C (-4°F to 122°F)
Accuracy: 0.44°C from 0°C to 50°C (0.79°F from 32°F to 122°F)
Resolution: 0.1°C at 25°C (0.18°F at 77°F)
Response Time (90%): 5 Minutes in Water (Typical)
Stability (Drift): 0.1°C (0.18°F) per Year
Customer Questions
Can water level data loggers be used for monitoring both fresh and saltwater environments?
Using Data Loggers in Freshwater and Saltwater Environments Whether you’re monitoring the chill of a deep freshwater lake or the relentless tides of an ocean bay, there are data logger options equipped to thrive. Many robust temperature and depth loggers...
Please, mind that only logged in users can submit questions