The store will not work correctly when cookies are disabled.
ACR Systems
-
01-0130
- (2) External Inputs for Externally-Generated Pulse Signals and Dry Switch Contact Closures
- Measures up to 4,095 Pulses per Sample Period with Accuracy of ±1 Pulse/Sample Period
- Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
- 25/second to 8 Hour User-Selectable Sampling Rate
- Continuous (FIFO) or Stop When Full Sampling Methods
-
01-0261
- Withstand Just About Any Environment with its Aluminum or Stainless Steel Housing
- -40°C to 85°C (-40°F to 185°F) Temperature Measurement Range with 0.2°C Accuracy (0°C to 70°C)
- Powered-By A 10-Year 3.6 Volt Lithium Battery
- 8 Seconds to 34 Minute User-Selectable Sampling Rate
- Designed to Handle Pressures up to 2000 PSI
-
01-0065
- Detects Surges, Sags, Impulses, Dropouts, Outages and Frequency Variations
- Monitor and Record Voltage Disturbances from a Power Plug Receptacle
- Stores up to 4,000 Events
- Powered by a Factory-Replaceable 10-Year 3.6 Volt Lithium Battery
- LED Flashing Light When Events are Recorded
- Includes EventReader Software and USB Cable for Creation of Easy to Understand Graphs
-
01-0011
- Measure & Record AC Current, Voltage and Temperature
- 8 Channels: (1) Temperature and (7) 0 to 5 Volts DC Inputs
- Temperature Measurement Range of -40°C to 70°C with a ±0.2°C Accuracy
- 3 Memory and Data Storage Options Available (32 KB, 128K and 1.5MB)
- 25/Second to 8 Hour User-Selectable Sampling Rate
- 3.6 Volt Lithium Battery with 10 Year Life (Factory Replaceable)
-
01-0310
- Measure and Record Low Differential Pressure and Temperature
- (5) Pressure Ranges Available with ±0.5% of Full Scale @ 25°C
- 25/second to 8 Hour User-Selectable Sampling Rate
- Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
- Continuous (FIFO) or Stop When Full Sampling Methods
-
01-0013
- (7) External Thermocouple Inputs and (1) Internal Temperature Sensor
- Accepts Type J, K, S, T or E Thermocouple Sensor Probes
- Internal Temperature Sensor Features A Measurement Range of -40°C to 70°C (-40°F to 158°F) and ±0.2°C Accuracy
- Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
- 25/Second to 8 Hour User-Selectable Sampling Rate
- Continuous (FIFO) or Stop When Full Sampling Methods
-
01-0263
- Withstand Just About Any Environment with its Aluminum or Stainless Steel Housing
- 10°C to 135°C (50°F to 275°F) Temperature Measurement Range with ±0.5°C Accuracy
- Powered-By A 3-Year 3.6 Volt Lithium Battery
- 8 Seconds to 34 Minute User-Selectable Sampling Rate
- Designed to Handle Pressures up to 2000 PSI
-
01-0132
- (3) External RTD Inputs and (1) Internal Thermistor Temperature Sensor
- Accepts Any 4-Wire Platinum 100/1000 Ohm RTD Sensor Probe with a TCR of 0.00385
- Internal Temperature Sensor Features A Measurement Range of -40°C to 70°C (-40°F to 158°F) and ±0.2°C Accuracy
- Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
- 25/Second to 8 Hour User-Selectable Sampling Rate
- Continuous (FIFO) or Stop When Full Sampling Methods
Copyright © 2024 MicroDAQ, LLC. All Rights Reserved.