Lascar Electronics
-
EL-WIFI-21CFR-DULT
- Designed for Monitoring Vaccines in Ultra Low Temperature Dry Ice Storage Environments
- Measure and Record Temperature Readings Using (2) Type T Thermocouple Sensor Probes (Included)
- Measurement Range of -100°C to 100°C and 2.5°C Accuracy
- Designed to Meet 21CFR Part 11 Compliance with Digital Signatures and Encryption
- Wirelessly Stream and View Data on the EasyLog 21CFR Cloud
- LCD Display Shows Live Data, Battery Status, Alarm Status
- Powered by Rechargeable Lithium Battery with Average 6 Month Battery Life
Includes (2) Type T Thermocouple Sensor Probes, USB Cable and Wall Mounting Bracket. 21CFR Part 11 Software Available for Download.
Calibration Certificate Not Included – Must be purchased separately below.
-
EL-WIFI-21CFR-DULT+
- Designed for Monitoring Vaccines in Ultra Low Temperature Dry Ice Storage Environments
- Measure and Record Temperature Readings Using (2) Type T Thermocouple Sensor Probes (Included)
- Measurement Range of -100°C to 100°C and 1.8°C Accuracy
- Designed to Meet 21CFR Part 11 Compliance with Digital Signatures and Encryption
- Wirelessly Stream and View Data on the EasyLog 21CFR Cloud
- LCD Display Shows Live Data, Battery Status, Alarm Status
- Powered by Rechargeable Lithium Battery with Average 6 Month Battery Life
Includes (2) Type T Thermocouple Sensor Probes, USB Cable and Wall Mounting Bracket. 21CFR Part 11 Software Available for Download.
Calibration Certificate Not Included – Must be purchased separately below.
-
EL-WIFI-21CFR-DTP+
- Record Temperature Using 2 External Thermistors
- Permission-Based Use, Authority Level-Sign-Off and Full System Audits Ensure 21CFR Part 11 Standards Met
- -40°C to 125°C Temperature Measurement Range with ±0.2°C Accuracy
- Requires a Paid WiFi 21CFR Cloud Service Subscriptions Starting at $179 per Year (Purchased during Setup Process)
- Logs up to 30 Days of Readings at 10 Second Sample Rate onto Internal Memory
- LCD Display Shows Current Temperature Readings, Battery Status and Alarm Status
Includes (2) 3-Meter Thermistor Probes, 160mm Y Splitter Cable, Rechargeable Lithium Battery, Micro USB Cable and Wall Bracket. PC Software Available as A Free Download.
-
EL-WIFI-21CFR-DTC
- Record Temperature Using Dual External Inputs Accepting Type J, K, T or N Thermocouples
- Permission-Based Use, Authority Level-Sign-Off and Full System Audits Ensure 21CFR Part 11 Standards Met
- 0°C to 200°C Temperature Measurement Range with ±1.5°C Accuracy (Included Thermocouple Probes)
- Requires a Paid WiFi 21CFR Cloud Service Subscriptions Starting at $179 per Year (Purchased during Setup Process)
- Logs up to 30 Days of Readings at 10 Second Sample Rate onto Internal Memory
- LCD Display Shows Current Temperature Readings, Battery Status and Alarm Status
Includes (2) Type K Thermocouple Probes, Rechargeable Lithium Battery, Micro USB Cable and Wall Bracket. PC Software (For Setup and Local Storage) Available as A Download.
-
EL-WIFI-21CFR-VAC2
- 2 External High Accuracy Thermistors for Vaccine Monitoring
- Permission-Based Use, Authority Level-Sign-Off and Full System Audits Ensure 21CFR Part 11 Standards Met
- -40°C to 125°C Temperature Measurement Range with ±0.2°C Accuracy
- Requires a Paid WiFi 21CFR Cloud Service Subscriptions Starting at $179 per Year (Purchased during Setup Process)
- Logs up to 30 Days of Readings at 10 Second Sample Rate onto Internal Memory
- LCD Display Shows Current Temperature Readings, Battery Status and Alarm Status
- Includes a NIST Traceable Calibration Certificate, Compliant to ISO/IEC 17025:2017
- Unless otherwise stated by the customer the calibration interval will default to the manufacturers recommendation of 1-Year
- Data Logger Calibrated for Both Fridge (5°C) and Freezer (-15°C) Use
- Can Be Used as Either Primary or Backup Data Logger
- Meets CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling
Includes NIST Traceable Calibration Certificate, (2) 3 Meter Thermistor Probes, 160mm Y Splitter Cable, Rechargeable Lithium Battery, Micro USB Cable and Wall Bracket. PC Software Available as A Free Download.
-
EL-WIFI-21CFR-VAC
- Measure and Record Temperature Using External Thermistor
- Permission-Based Use, Authority Level-Sign-Off and Full System Audits Ensure 21CFR Part 11 Standards Met
- -40°C to 125°C Temperature Measurement Range with ±0.5°C Accuracy
- Requires a Paid WiFi 21CFR Cloud Service Subscriptions Starting at $179 per Year (Purchased during Setup Process)
- Logs up to 1 Million Readings onto Internal Memory if Wireless Network Not Available
- Includes a NIST Traceable Calibration Certificate, Compliant to ISO/IEC 17025:2017
- Unless otherwise stated by the customer the calibration interval will default to the manufacturers recommendation of 1-Year
- Data Loggers are Calibrated for Both Fridge (5°C) and Freezer (-15°C) Use
- Can Be Used as Either Primary or Backup Data Logger
- Meets CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling
Includes NIST Traceable Calibration Certificate, 3 Meter Thermistor Probe with Attached Glycol Bottle, Rechargeable Lithium Battery, Micro USB Cable and Wall Bracket. PC Software (For Setup and Local Storage) Available as A Download.