  1. Lascar 21CFR WiFi Dual Channel Thermistor Vaccination Kit
    EL-WIFI-21CFR-VAC2
    • 2 External High Accuracy Thermistors for Vaccine Monitoring
    • Permission-Based Use, Authority Level-Sign-Off and Full System Audits Ensure 21CFR Part 11 Standards Met
    • -40°C to 125°C Temperature Measurement Range with ±0.2°C Accuracy
    • Requires a Paid WiFi 21CFR Cloud Service Subscriptions Starting at $179 per Year (Purchased during Setup Process)
    • Logs up to 30 Days of Readings at 10 Second Sample Rate onto Internal Memory
    • LCD Display Shows Current Temperature Readings, Battery Status and Alarm Status
    • Includes a NIST Traceable Calibration Certificate, Compliant to ISO/IEC 17025:2017
    • Unless otherwise stated by the customer the calibration interval will default to the manufacturers recommendation of 1-Year
    • Data Logger Calibrated for Both Fridge (5°C) and Freezer (-15°C) Use
    • Can Be Used as Either Primary or Backup Data Logger
    • Meets CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling

    Includes NIST Traceable Calibration Certificate, (2) 3 Meter Thermistor Probes, 160mm Y Splitter Cable, Rechargeable Lithium Battery, Micro USB Cable and Wall Bracket. PC Software Available as A Free Download.

  2. Lascar 21CFR WiFi Thermistor Vaccine Monitoring Kit
    EL-WIFI-21CFR-VAC
    • Measure and Record Temperature Using External Thermistor
    • Permission-Based Use, Authority Level-Sign-Off and Full System Audits Ensure 21CFR Part 11 Standards Met
    • -40°C to 125°C Temperature Measurement Range with ±0.5°C Accuracy
    • Requires a Paid WiFi 21CFR Cloud Service Subscriptions Starting at $179 per Year (Purchased during Setup Process)
    • Logs up to 1 Million Readings onto Internal Memory if Wireless Network Not Available
    • Includes a NIST Traceable Calibration Certificate, Compliant to ISO/IEC 17025:2017
    • Unless otherwise stated by the customer the calibration interval will default to the manufacturers recommendation of 1-Year
    • Data Loggers are Calibrated for Both Fridge (5°C) and Freezer (-15°C) Use
    • Can Be Used as Either Primary or Backup Data Logger
    • Meets CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling

    Includes NIST Traceable Calibration Certificate, 3 Meter Thermistor Probe with Attached Glycol Bottle, Rechargeable Lithium Battery, Micro USB Cable and Wall Bracket. PC Software (For Setup and Local Storage) Available as A Download.

  3. Lascar 21CFR USB Thermocouple Data Logger
    EL-21CFR-TC
    • Measure and Record Temperature Readings Using Type J, K or T Thermocouple Sensor Probe
    • Designed to Meet 21CFR Part 11 Compliance with Digital Signatures and Encryption
    • Stores 32,510 Temperature Readings onto Non-Volatile Internal Memory
    • Direct USB Connection for Data Download on to Desktop PC for Analysis
    • Powered by User-Replaceable 1/2 AA Lithium Battery with up to 2 Year Battery Life

    Includes Type K Thermocouple Sensor Probe, Protective Cap and 1/2 AA Lithium Battery and 21CFR Part 11 Software Available for Download.

  4. Lascar 21CFR USB Thermistor Data Logger w/ LCD Display
    EL-21CFR-TP-LCD
    • Designed to Meet 21CFR Part 11 Compliance with Digital Signatures and Encryption
    • Measure and Record Temperature Readings Using External Sensor
    • -35°C to 80°C Measurement Range with 0.5°C Accuracy
    • Stores 16,382 Temperature Readings onto Non-Volatile Internal Memory
    • Powered by User-Replaceable 1/2 AA Lithium Battery with up to 2 Year Battery Life
    • High Contrast LCD Displays Temperature, 2 1/2 Digits

    Includes Protective Cap and 1/2 AA Lithium Battery and 21CFR Part 11 Software Available for Download.

  5. Lascar 21CFR USB Better Accuracy Thermistor Data Logger w/ LCD Display
    EL-21CFR-TP-LCD+
    • Designed to Meet 21CFR Part 11 Compliance with Digital Signatures and Encryption
    • Measure and Record Temperature Readings Using External Sensor
    • -35°C to 80°C Measurement Range with ±0.3°C Accuracy
    • Stores 16,382 Temperature Readings onto Non-Volatile Internal Memory
    • Powered by User-Replaceable 1/2 AA Lithium Battery with up to 2 Year Battery Life
    • High Contrast LCD Displays Temperature, 2 1/2 Digits

    Includes EL-P-TP+ Thermistor Probe, Mounting Bracket, Protective Cap and 1/2 AA Lithium Battery and 21CFR Part 11 Software Available for Download.

  6. Lascar 21CFR USB Humidity and Temperature Data Logger w/ LCD Display
    EL-21CFR-2-LCD
    • Designed to Meet 21CFR Part 11 Compliance with Digital Signatures and Encryption
    • Measure and Record Temperature, Humidity and Dew Point Readings Using Internal Sensor
    • -35°C to 80°C and 0 to 100% RH Measurement Range
    • Stores 16,382 Temperature and 16,382 Humidity Readings onto Non-Volatile Internal Memory
    • Powered by User-Replaceable 1/2 AA Lithium Battery with up to 2 Year Battery Life
    • High Contrast LCD Displays Temperature and Humidity, 2 1/2 Digits

    Includes Protective Cap and 1/2 AA Lithium Battery and 21CFR Part 11 Software Available for Download.

  7. Lascar 21CFR Better Accuracy USB Humidity and Temperature Data Logger w/ LCD Display
    EL-21CFR-2-LCD+
    • Designed to Meet 21CFR Part 11 Compliance with Digital Signatures and Encryption
    • Measure and Record Temperature, Humidity and Dew Point Readings Using Internal Sensor
    • -35°C to 80°C and 0 to 100% RH Measurement Range
    • ±0.5°C Temperature and ±2.05%RH Humidity Accuracy
    • Stores 16,382 Temperature and 16,382 Humidity Readings onto Non-Volatile Internal Memory
    • Powered by User-Replaceable 1/2 AA Lithium Battery with up to 2 Year Battery Life
    • High Contrast LCD Displays Temperature and Humidity, 2 1/2 Digits

    Includes Protective Cap and 1/2 AA Lithium Battery and 21CFR Part 11 Software Available for Download.