Onset Computer Corp.

2 Items

Set Descending Direction
per page
  1. InTemp Vaccine Monitoring Data Logger
    CX402-VFC205
    • External Sensor for Vaccine Monitoring of Refrigerators and Freezers
    • Wireless Transmission of Recorded Readings to Smart Phones and Tablets Using Bluetooth Smart LE Communications
    • ±0.5°C Accuracy in a -22°C to 50°C Measurement Range
    • User-Replaceable Lithium Battery with 1 Year Typical Life (1 Minute Sampling Rate)
    • Stores up to 84,650 Measured Readings with Date/Time Stamp if Bluetooth Communications Not Available
    • LCD Display Showing Current Readings and Audible/Visual Alarms
    • Includes a NIST Traceable Calibration Certificate, Compliant to ISO/IEC 17025:2017
    • Unless otherwise stated by the customer the calibration interval will default to the manufacturers recommendation of 3-Years
    • Data Loggers are Calibrated for Both Fridge (5°C) and Freezer (-15°C) Use
    • Available in 2 or 4 Meter Temperature Probe Lengths and 5, 15 or 30 ml Glycol Solution Bottles
    • Meets CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling

    Includes Glycol Bottle and NIST Traceable Calibration Certificate. InTemp and InTempConnect Apps Available on the Apple and Android Stores

  2. InTemp® Fridge & Freezer Starter Kit with Real-Time Alert Notifications
    CX402-VFC215-GATEWAY-KIT
    • Internal and External Sensor for Vaccine Monitoring of Refrigerators and Freezers
    • Wireless Bluetooth Transmission of Recorded Readings from Data Loggers to InTemp Gateway
    • ±0.5°C Accuracy in a -22°C to 50°C Measurement Range
    • User-Replaceable Lithium Battery with 1 Year Typical Life (1 Minute Sampling Rate)
    • InTemp Gateway Manages the Communications Between Data Loggers and Cloud Interface
    • The CX5000 Gateway connects seamlessly to the InTemp Connect Cloud-Based Platform for Online Monitoring
    • 3-Year Calibration Certificate - Performed by ISO/IEC 17025:2017 Accredited Lab by PJLA (PJLA Accredited by ILAC and APLAC)
    • Included Data Loggers Can be used as a Primary or Backup
    • Meets CDC & VFC (Vaccines for Children) Program Recommendations for Safe Vaccine Storage & Handling

    Includes InTemp CX Gateway with Mounting Kit and AC Adapter, (2) CX402-VFC215 Data Loggers w/ 15ml Glycol Bottle, 2 Meter Probe Length and NIST Traceable Calibration Certificate. InTemp and InTemp Connect Apps Available on the Apple and Android Stores

    **Not eligible for returns once Gateway has been activated**

per page