Sensors and Probes
-
Onset 4" Rogowski Coil Sensor$140.00T-EG-4000-2775
- 6ft Twisted Pair Lead with CT Connector
- Accurate within 1% from 30A to Stated Current Rating
- Window Size: 4.17"
- Coil Length: 15.75"
- External Diameter: 5.63"
- Coil Diameter: 15.5"
- Output: 333 mVrms at Rated Output
- Note: 30A Minimum Current Required at All Times. No External Integrator Required.
Includes 2-Pin CT Connector Plug
-
Onset 7" Rogowski Coil Sensor$150.00T-EG-7000-2775
- 6ft Twisted Pair Lead with CT Connector
- Accurate within 1% from 30A to Stated Current Rating
- Window Size: 7.01"
- Coil Length: 23.62"
- External Diameter: 8.13"
- Coil Diameter: 15.5"
- Output: 333 mVrms at Rated Output
- Note: 30A Minimum Current Required at All Times. No External Integrator Required.
Includes 2-Pin CT Connector Plug
-
RXW-RGE-900
- Wireless Rainfall Sensor with 0 to 4 inches Measurement Range
- ±4.0% Accuracy in 0 to 2 inch Range and ±5% Accuracy in 2 to 4 inch Range
- 450 to 600 Meter Wireless Range and up to 5 Extended Hops with a Wireless Repeater
- Simple Push Button Setup for Joining a HOBOnet Wireless Network
- Powered by a Rechargeable AA Batteries and Built-In Solar Panel or Lithium Batteries
- Operates in an Outdoor Environment with a Solar Radiation Shield
- Available in 4 Wireless Frequencies: 900 MHz (Americas), 868 MHz (Europe), 922 MHz (Australia/New Zealand) and 921 MHz (Taiwan)
A Complete System Requires an RX3000 Remote Monitoring Station or RX2100 MicroRX Monitoring System, HOBOnet Wireless Manager and HOBOnet Wireless Sensor
-
TMC1-HD
- -40°C to 50°C (-40°F to 122°F) Measurement Range in Water or Soil
- -40°C to 100°C (-40°F to 212°F) Measurement Range in Air
- 3 Minutes (Air) and 1 Minute (Water, Soil) Response Time
- Stainless Steel Sensor Tip
- Probe dimensions: 0.5 cm x 2.5 cm (0.20" x 1.0")
Cable Available in 1 ft, 6 ft, 20 ft and 50 ft Lengths
-
TMC6-HC
- Measurement Range: -40°C to 100°C (-40°F to 212°F) in Air or Water
- 102 mm (47quot;) Food-Grade Stainless Steel Probe with Pointed Tip; 3 mm (0.12") Diameter
- Drift: < 0.1°C (0.2°F ) per year
- Response Time in Air: 3 Minutes Typical to 90% in Air Moving 1 m/sec (2.2 mph)
- Response Time in Stirred Water: 15 Seconds Typical
Includes 1.8 Meter (6ft) Cable
-
Onset Air Temperature Sensor$69.00TMC6-HE
- Fast Response Probe with Plated Copper Sensor Tip
- Suitable for Pipe Mounting
- Measurement Range: -40°C to 100°C
- Cable Length: 1.8 Meters (6 ft)
Includes Tie Wraps, Screw and Thermal Grease
-
Onset Thermocouple, 12"$65.00TCP6-K12
- 30cm (12") High-Temp Stainless Steel Probe with 0.5cm diameter
- 2.5cm (1") Handle with Spring-Type Strain Relief with 6ft 19 AWG Wire
- Measurement Range: 0°C to 900°C
- Cable Length: 6 Feet
- Includes Mini Connector