Sensors and Probes
-
HOBO Wind Speed Smart Sensor$299.00S-WSB-M003
- Uses 3-Cup Anemometer
- Plug-In Modular Connection
- Measurement Range: 0 to 76 m/s (0 to 170 mph)
- Accuracy: ±1.1 m/s (2.4 mph) or 4% of Reading Whichever is Greater
- Cable Length: 3 Meters
-
S-LIA-M003
- Measures the Light Range that Effects Photosynthesis (PAR - Photosynthetically Active Radiation)
- 400 nm to 700 nm Frequency Measurement Range with ±5 umol.m2/sec or ±5%
- -40°C to 75°C Operating Temperature Range
- Constructed of Anodized Aluminum Housing with Acrylic Diffuser and O-Ring Seal
Includes 3 Meter Cable Length
-
Onset Silicon Pyranometer$270.00S-LIB-M003
- Measure Solar Radiation Light Levels Using Silicon Pyranometer
- 0 to 1280 W/m2 Measurement Range over a Spectral Range of 300 to 1100 nm
- Records the Average Light Intensity over the Pre-Determined User-Set Logging Interval
- -40°C to 75°C Operating Temperature Range
- Housing Constructed of Anodized Aluminum and Acrylic Diffuser and O-Ring Seal
-
Rain Gauge Smart Sensor (0.01")$269.00S-RGE-M002
- New! AeroCone® Design for Better Measurement Accuracy in High-Wind Conditions
- Cost Effective way of Measuring Rainfall on HOBO Weather Stations
- Measurement Range of 0 to 10.2cm (0 to 4in.) per Hour
- Plug-in Modular Connector for Easy Installation
- Data Stored in Sensor & Automatically Communicates to Attached Data Logger (Sold Separately)
- Compatible with Onset RX3000, U30, H21-002 and H22-001
-
Rain Gauge Smart Sensor (0.2mm)$269.00S-RGF-M002
- New! AeroCone® Design for Better Measurement Accuracy in High-Wind Conditions
- Cost Effective way of Measuring Rainfall on HOBO Weather Stations
- Measurement Range of 0 to 10.2cm (0 to 4in.) per Hour
- Plug-in Modular Connector for Easy Installation
- Data Stored in Sensor & Automatically Communicates to Attached Data Logger (Sold Separately)
- Compatible with Onset RX3000 Series, U30, H21-USB and H22-001
-
Onset Barometric Pressure Sensor$299.00S-BPB-CM50
- Automatic Communication of Configuration Information to Data Logger without Setup
- 12-Bit Resolution with Rugged, Outdoor Rated Weatherproof Housing
- 660 to 1070 mbar Measurement Range with ±3.0 mbar Accuracy
- 1.0 mbar Drift per Year
- 50 cm Cable Length
Includes (2) Cable Ties and (2) #8 Self Tapping Screws
-
Ashcroft Gauge Pressure Sensor$269.00T-ASH-G2-100
- Precision Pressure Measurements in Compressed Air Systems, Water or Oter Gases and Fluids
- Accuracy: ±1% to 1.5% FS
- Connection: 1/4" NPT 305 Stainless Steel
- Output Signal: 0 to Volts DC, 3 Wire
- Available in 100 PSIG, 200 PSIG and 500 PSIG Pressure Ranges
Requires Analog Port Selection During U30 or RX3000 Series System Configuration and Use of a S-FS-CVIA when using the H22-001 Data Logger. When using a U12 or UX120 Series Data Loggers, this Sensor Requires a 0-5 VDC Analog Input Cable (CABLE-ADAP5) and External Power Provided by an AC Adapter (AC-SENS-1).