TandD

Items 9-16 of 93

Set Descending Direction
  1. TCM-3010 Thermocouple Input Module
    TCM-3010
    • Sensors: Accepts Type K, J, T and S Thermocouple Sensor Probes
    • Measurement Range (Type K): -199C to 1370C
    • Measurement Range (Type J): -199C to 1200C
    • Measurement Range (Type T): -199C to 400C
    • Measurement Range (Type S): -50C to 1760C
    • Accuracy (Type K): ±(0.3°C + 0.3% of Reading)
    • Accuracy (Type J): ±(0.3°C + 0.3% of Reading)
    • Accuracy (Type T): ±(0.3°C + 0.3% of Reading)
    • Accuracy (Type S): ±(1.0°C + 0.3% of Reading)
    • Cold Junction Compensation (10°C to 40°C):±0.3°C
    • Cold Junction Compensation (-40°C to 10°C):±0.5°C
    • Cold Junction Compensation (40°C to 80°C):±0.5°C
    • Measurement Resolution (Type K): 0.1°C
    • Measurement Resolution (Type J): 0.1°C
    • Measurement Resolution (Type T): 0.1°C
    • Measurement Resolution (Type S): 0.2°C
    • Compatible with the RTR-505B Input Module Data Logger

    Requires Type K, J, T or S Thermocouple Probe

  2. VIM-3010 Voltage Input Module
    VIM-3010
    • Measurement Range: 0 to 22 Volts
    • Accuracy (10°C to 40°C): ±(0.5 mV + 0.3% of Reading)
    • Accuracy (-40°C to 10°C): ±(1.0 mV + 0.5% of Reading)
    • Accuracy (40°C to 80°C): ±(1.0 mV + 0.5% of Reading)
    • Measurement Resolution (Up to 400 mV): 0.1 mV
    • Measurement Resolution (Up to 800 mV): 0.2 mV
    • Measurement Resolution (Up to 999 mV): 0.4 mV
    • Measurement Resolution (Up to 3.2 V): 1 mV
    • Measurement Resolution (Up to 6.5 V): 2 mV
    • Measurement Resolution (Up to 9.999 V): 4 mV
    • Measurement Resolution (Up to 22 V): 10 mV
    • Compatible with the RTR-505B Input Module Data Logger
  3. TandD TR43A Bluetooth Temperature and Humidity Data Logger
    TR43A
    • External Sensor for Humidity and Temperature Measurements in an Indoor Environment
    • Wireless Transmission of Recorded Readings to Phone or Tablet Using Bluetooth Smart LE Communications
    • 0C to 55C Temperature and 0 to 95% RH Measurement Ranges with a ±0.5°C and ±5.0% RH Accuracy
    • User-Replaceable Lithium Battery with 1.5 Year Typical Life (10 Minute Sampling Rate)
    • Stores up to 16,000 Measured Readings with Date/Time Stamp if Bluetooth Communications Not Available
    • Compatible with the Free TandD WebStorage Cloud Service for Viewing your Recorded Readings Anywhere, Anytime
    • ThermoREC and ThermoStorage Apps Available from Apple Store and Google Play for Setup and Reporting
    • New! TR4 Report App for Viewing, Annotating, Saving and Emailing Reports. Available for iOS.

    Includes THB3001 Temp-Humidity Sensor, 1/2 AA Lithium Battery and Strap