  1. Ethernet LAN Better Accuracy Humidity and Temperature Data Logger with External Sensors
    TR-72NW-S
    • Measure and Record Temperature and Humidity Readings Using External Sensor Probes
    • -40°C to 80°C Temperature and 8 to 95% RH Measurement Ranges with ±0.3°C and ±2.5% RH Accuracy
    • Stores up to 8,000 Readings Between Data Transfers to PC or TandD WebStorage Cloud Service
    • USB or Ethernet LAN Connectivity (Cloud Storage Requires Ethernet and Free Cloud Storage Account)
    • Automatic Transmission of Data (Current or Logged) at Set Interval Using Wired Network and Cloud Storage

    Includes Humidity/Temperature Sensor (SHA-3151), T&D PC Software Available as a Download, (2) AA Alkaline Batteries and User Manual.

    NOTE: Setup Requires Advanced Understanding of Network Connectivity & Security Settings. Not Compatible with Enterprise Wireless Network Security.

  2. TCM-3010 Thermocouple Input Module
    TCM-3010
    • Sensors: Accepts Type K, J, T and S Thermocouple Sensor Probes
    • Measurement Range (Type K): -199C to 1370C
    • Measurement Range (Type J): -199C to 1200C
    • Measurement Range (Type T): -199C to 400C
    • Measurement Range (Type S): -50C to 1760C
    • Accuracy (Type K): ±(0.3°C + 0.3% of Reading)
    • Accuracy (Type J): ±(0.3°C + 0.3% of Reading)
    • Accuracy (Type T): ±(0.3°C + 0.3% of Reading)
    • Accuracy (Type S): ±(1.0°C + 0.3% of Reading)
    • Cold Junction Compensation (10°C to 40°C):±0.3°C
    • Cold Junction Compensation (-40°C to 10°C):±0.5°C
    • Cold Junction Compensation (40°C to 80°C):±0.5°C
    • Measurement Resolution (Type K): 0.1°C
    • Measurement Resolution (Type J): 0.1°C
    • Measurement Resolution (Type T): 0.1°C
    • Measurement Resolution (Type S): 0.2°C
    • Compatible with the RTR-505B Input Module Data Logger

    Requires Type K, J, T or S Thermocouple Probe

  3. VIM-3010 Voltage Input Module
    VIM-3010
    • Measurement Range: 0 to 22 Volts
    • Accuracy (10°C to 40°C): ±(0.5 mV + 0.3% of Reading)
    • Accuracy (-40°C to 10°C): ±(1.0 mV + 0.5% of Reading)
    • Accuracy (40°C to 80°C): ±(1.0 mV + 0.5% of Reading)
    • Measurement Resolution (Up to 400 mV): 0.1 mV
    • Measurement Resolution (Up to 800 mV): 0.2 mV
    • Measurement Resolution (Up to 999 mV): 0.4 mV
    • Measurement Resolution (Up to 3.2 V): 1 mV
    • Measurement Resolution (Up to 6.5 V): 2 mV
    • Measurement Resolution (Up to 9.999 V): 4 mV
    • Measurement Resolution (Up to 22 V): 10 mV
    • Compatible with the RTR-505B Input Module Data Logger