16 Channel 500 k/s High-Speed Multifunction DAQ Device

Measurement Computing USB-1608G Series Data Acquisition w/ Single-Ended & Differential Analog Inputs
SKU
USB-1608GX
$689.00
  • (16) Analog Inputs, (8) Independent Digital I/Os, (2) Counter Inputs and (1) Timer
  • 1 S/s to 1MS/s Sampling Rate, Software Programmable
  • Single and Differential Analog Inputs w/ Measurement Range up to ±10 Volts
  • Measurement Rate up to 500 k/S Aggregated Over All Analog Input Channels
  • Powered by 5 Volt USB Supply from Your PC Computer, No External AC Power Required

Includes USB Cable and Measurement Computing DAQ Software Suite (DAQami, TracerDAQ, InstaCal, Universal Libraries for Windows, Android and NI LabVIEW) Available as a Download

Due to product shortages lead times on most Measurement Computing orders will range from 7-16 weeks.
Software Downloads
zip
(Size: 32.96 MB)
exe
(Size: 361.69 MB)
Version 6.75
User Manuals and Product Guides
pdf
(Size: 0.01 MB)
This Document is Required to be Filled out by Anyone Outside the United States Purchasing a Measurement Computing Product.
Product Videos

Measurement Computing USB-1608GX High Speed USB Data Acquisition DAQ Module Specifications

Analog Input A/D Converter Type: Successive Approximation
ADC Resolution: 16 Bits
Channels*: 8 (Differential); 16 (Single-Ended)
Input Voltage Range*: ±10V; ±5V; ±2V; ±1V per Channel
Input Impedance: 1GΩ (Power On); 820Ω (Power Off)
Input Bias Current: ±10 nA
Input Bandwidth: 870 kHz (All Input Ranges, -3dB Signal)
Input Capacitance: 60 pf
Sampling Rate*: 0.0149 Hz to 500 kHz
Burst Mode**: 2 µs
Throughput: 33 - 4000 S/s (Software); 500 kS/s (Hardware)
* Software Selectable
** Software-Selectable Using the Internal A/D Clock; Always Enabled When using the External Clock (AICKI Command)
Digital I/O Digital Type: CMOS
Number of I/O: 8
Configuration: Each bit Input or Output
Transfer Rate: 33 to 8000 port Reads/Writes or Single Bit Reads/Writes Per Second
Input High Voltage: 2.0 Volts (Min); 5.5 Volts (Max)
Input Low Voltage: 0.8 Volt (Max); -0.5 Volt (Min); 0 Volt Recommended
Output High Voltage: 4.4 V Min (IOH= -50uA); 3.76 Volt Min (IOH= -2.5 mA)
Output Low Voltage: 0.1 V Max (IOL= 50uA); 0.44 Volt Max (IOL= 2.5 mA)
Output Current: ±2.5 mA Max
External Trigger Trigger Source: TRIG input
Trigger Mode: Edge or Level Sensitive, Rising or Falling Edge, High or Low Level
Trigger Latency: 1 µs + 1 clock Cycle Max
Pulse Width: 100 ns Min
Input Type: Schmitt Trigger, 33 Ω Series Resistor and 49.9 kΩ Pull-Down to Ground
Input High Voltage: 2.2 Volt (Min); 5.5 Volt (Max)
Input Low Voltage: 1.5 Volt (Max); -0.5 Volt (Min); 0 Volt (Recommended)
External Clock I/O Input Clock Rate: 500 kHz Max
Clock Pulse Width: 400 ns Min (Input and Output)
Input Type: Schmitt Trigger, 33 Ω Series Resistor and 49.9 kΩ Pull-Down to Ground
Schmitt Trigger Hysteresis: 0.4 Volt to 1.2 Volt
Input High Voltage: 2.2 Volt (Min); 5.5 Volt (Max)
Input Low Voltage: 1.5 Volt (Max); -0.5 Volt (Min); 0 Volt (Recommended)
Output High Voltage: 4.4 V Min (IOH= -50uA); 3.76 Volt Min (IOH= -2.5 mA)
Output Low Voltage: 0.1 V Max (IOL= 50uA); 0.44 Volt Max (IOL= 2.5 mA)
Output Current: ±2.5 mA Max
Counter Channels: 2 (CTR0 and CTR1)
Resolution: 32-bit
Counter Type: Schmitt Trigger, 33 Ω Series Resistor and 49.9 kΩ Pull-Down to Ground
Schmitt Trigger Hysteresis: 0.4 Volt to 1.2 Volt
Input Source: Terminal 52 (CTR0); Terminal 51 (CTR1)
Read/Write Rates*: 33 to 8000 Reads/Wrires per Second
Input High Voltage: 2.2 Volt (Min); 5.5 Volt (Max)
Input Low Voltage: 1.5 Volt (Max); -0.5 Volt (Min)
Input Frequency: 20 MHz Max
High Pulse Width: 25 ns Min (Low and High)
Timer Output Type: PWM Output with Count, Period, Delay and Pulse width Registers
Output Value: Default State is Idle Low with Pulses High, Software-Selectable Output Invert
Internal Clock Frequency: 64 MHz
Register Widths: 32-Bit
Pulse Width: 15.625 ns Min (Low and High)
Output High Voltage: 4.4 Volt Min (IOH @ -50 µA); 3.76 Volt Min (IOH @ -2.5mA)
Output Low Voltage: 0.1 Volt Max (IOL @ 50 µA); 0.44 Volt Max (IOL @ 2.5 mA)
Output Current: ±2.5 mA Maximum
Memory Data FIFO: 4kS (Analog Input); 2 kS (Analog Output)
Non-Volatile: 32 KB (28KB - Firmware; 4KB User Data)
Quiescent Current 260 mA*
* Includes 10 mA for Status LEDs. Doesn't include potential loading of Digital I/O Bits or +5 Volt Terminal
Operating Range Temperature: 0°C to 55°C Max
Humidity: 0% to 90% RH Non-Condensing Max
Storage Range Temperature: -40°C to 85°C Max
Humidity: 0% to 90% RH Non-Condensing Max
OS Compatibility Windows 11, 10 and 7 (32 and 64-Bit) for Universal Library, LabVIEW
Dimensions 12.7 cm x 8.9 cm x 3.5 cm (5.0" x 3.53" x 1.40")
User Connection Length: 3 Meters (9.84 feet) Max.