MSR145 Miniature Signal Data Recorder

MSR Electronics Data Recorder Measures and Records Temperature, Humidity, Pressure, Light, Acceleration and 2 or 4 Additional Analog Inputs Available
SKU
MSR145
Please open the Configurator tab to choose your desired options.
  • Measures Temperature, Humidity, Light, Pressure and Acceleration Simultaneously and 2 or 4 Analog Inputs Also Available
  • Stores up to 2 Million (Internal Memory) or 1 Billion (SD Card) Total Readings
  • Rechargeable 900 mAh Lithium Polymer Battery
  • Data from any number of loggers can be merged synchronously into a single Data Record
  • Accelerometer Range of ±15g with -20°C to 65°C Temperature Range
  • Made in Switzerland, Swiss Made Swiss Made - Made in Switzerland

Includes Software CD, USB Cable and 4GB microSD Card

Click on the "Configurator" Tab Below to Choose the Ordering Options

MSR Data Loggers are Built to Order and Not Eligible for Return. All Sales Are Final.
Special order - please allow 3-4 weeks for this item to ship.

MSR145: Mini Data Logger for Temperature, Humidity, Air Pressure, Fluid Pressure, Light, Acceleration

award-winning universal data logger · stores up to 2 million or 1 billion (SDcard) total readings · large selection of housings, battery capacities, sensors and connectors

Product features Universal Data Logger MSR145

  • High-performance mini data logger for temperature, humidity, fluid pressure, air pressure, acceleration, light and more
  • Measures and records up to six different measurement parameters simultaneously
  • Wide range of housings, batteries, internal and external sensors, connectors (see Configurator)
  • Freely selectable measurement rates of up to 50 values per second
  • 3-axis-acceleration sensor ±15 g with Fast Peak (1 kHz)
  • Connector for thermal element of Type K
  • 2 or 2 or 4 analog inputs available
  • Recording time of of up to two years, depending on the battery and the measurement rate
  • Lithium-polymer battery 230 mAh or 1000 mAh, rechargeable via USB port
  • Stores up to 2 million (internal memory) or 1 billion (microSD Card) total readings
  • Small in size, light in weight
  • Free MSR PC software: MSR Setup, Reader, Viewer and Online software

With a few clicks you are able to select your desired MSR145.

1. Select the housing and the corresponding battery.

Housing Type and battery Picture Size & weight Medium Sheat
material
Item no.
Standard
IP 60
Design housing
with 230 mAh battery
MSR145S 27 x 16 x 53 mm
(W x H x L)
approx. 20 g
Air PC, not
encapsulated
145B15
Error
Design housing
with 900 mAh battery
MSR145 900 mAh 39 x 23 x 72 mm
(W x H x L)
approx. 56 g
Air PC, not
encapsulated
145B7
Error
Waterproof
IP 67
Silicon tube
with 230 mAh battery
MSR145W 20 x 14 x 62 mm
(W x H x L)
approx. 18 g
Air,
various liquids
Silicon,
encapsulated
145B4
Error
Design housing
with 230 mAh battery
MSR145WS 27 x 16 x 53 mm
(W x H x L)
approx. 27 g
Air,
various liquids
PC,
encapsulated
145B16
Error
Design housing
with 900 mAh battery
MSR145 900 mAh 39 x 23 x 72 mm
(W x H x L)
approx. 64 g
Air,
various liquids
PC,
encapsulated
145B8
Error

2. Select the sensors.

Please select the sensors for your data logger here. For the measured parameters temperature, humidity and fluid pressure you can now choose whether you wish to provide your MSR145 data logger with more than one sensor of the same measured parameter. Please note the following restrictions for this option:

  • Only one measured parameter can be equipped with multiple sensors.
  • The slot for a microSD card cannot be combined with this option.
  • The light sensor (L), the temperature sensor (FT) and the port for a thermal element of Type K (T3, T4) cannot be selected.

Can your desired sensor combination not be selected? Contact us for a customized fit.

Measured parameter /
Measuring/storage rate
Working range /
Accuracy
Internal
sensor
External sensor (according to cable length)
0.20 m 1.00 m 1.60 m
Temperature

1/s to every 12 h
-10...+58 °C
±0.1 °C (+5...+45 °C)
±0.2 °C (-10...+58 °C)
only available
externally
Item no. FT/020
Error
Item no. FT/100
Error
Item no. FT/160
Error
external: -55...+125 °C
internal: -20...+65 °C

±0.5 °C (-10...+65 °C)
±2 °C (-55...+125 °C)
Item no. T2
Error
Item no. FT2/020
Error

Item no. FT2/100
Error

Item no. FT2/160
Error

Connector for thermal
element of Type K

(without sensor)
Cannot be selected
at the same time as the
temperature sensor.

4/s to every 12 h
1 x
-200...+1350 °C
only available
externally
Item no. FT3/020
Error
Item no. FT3/100
Error
Item no. FT3/160
Error
4 x
-200...+1350 °C
only available
externally
Item no. FT4/020
Error
Item no. FT4/100
Error
Item no. FT4/160
Error
Humidity
with integrated temperature

1/s to every 12 h
0...100 % rel. humidity
external: -20...+85 °C
internal: -20...+65 °C

±2 % rel. humidity
(10...85 %, 0...+40 °C)
±4 % rel. humidity
(85...95 %, 0...+40 °C)
Item no. H3
Error
Item no. FH2/020
Error

Item no. FH2/100
Error

Item no. FH2/160
Error

Air pressure absolute,
with integrated temperature

10/s to every 12 h
0...2000 mbar absolute
external: -20...+85 °C
internal: -20...+65 °C

±2.5 mbar
(750...1100 mbar absolute,
+25 °C)
Item no. P5
Error
Item no. FP10/020
Error
Item no. FP10/100
Error
Item no. FP10/160
Error
0...14 bar absolute
-20...+65 °C

±50 mbar
(1...10 bar abs., +25 °C)
Item no. P7
Error
Item no. FP7/020
Error
Item no. FP7/100
Error
Item no. FP7/160
Error
Fluid pressure
with integrated temperature

20/s to every 12 h

Material in contact with media:
  • Stainless Steel AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-rings: Viton® 70° Shore
-1000...3000 mbar relative
-20...+85 °C

±30 mbar
only available
externally
Art.-Nr. FP9/020
Error

Art.-Nr. FP9/100
Error

Art.-Nr. FP9/160
Error

0...3000 mbar absolute
-20...+85 °C

±30 mbar
only available
externally
Item no. FP3/020
Error

Item no. FP3/100
Error

Item no. FP3/160
Error

0...30 bar absolute
-20...+85 °C

±300 mbar
only available
externally
Item no. FP4/020
Error

Item no. FP4/100
Error

Item no. FP4/160
Error

0...400 bar absolute
-20...+85 °C

±4 bar
only available
externally
Art.-Nr. FP8/020
Error

Art.-Nr. FP8/100
Error

Art.-Nr. FP8/160
Error

0...1000 bar absolute
-20...+85 °C

±10 bar
only available
externally
Art.-Nr. FP12/020
Error

Art.-Nr. FP12/100
Error

Art.-Nr. FP12/160
Error

3-axis-acceleration

50/s to every 12 h
±15 g
-20...+65 °C

±0.15 g (0...5 g, +25 °C)
±0.25 g (5...10 g, +25 °C)
±0.45 g (10...15 g, +25 °C)
Item no. A
Error
Item no. FA/020
Error
Item no. FA/100
Error
Item no. FA/160
Error
3-axis-acceleration
with Fast Peak (1 kHz)


50/s to every 12 h
Item no. A4
Error
Item no. FA4/020
Error
Item no. FA4/100
Error
Item no. FA4/160
Error
Light

1/s to every 12 h
0...65 000 lx
max. sensitivity
at 500 nm
Item no. L2
Error
Item no. FL2/020
Error
Item no. FL2/100
Error
Item no. FL2/160
Error

3. Do you require 2 or 4 analogue inputs?

Should you wish to connect additional third-party external sensors to your MSR145 datalogger then please indicate here whether you require two or four analogue inputs.

Analogue inputs Inputs Input configuration Item no.
Schraubklemme für 4 analoge Eingänge

Including alarm output and input for starting
and stopping data recording.

Measurement/storage rate:
50/s to every 12 h

Not available combinations:
  • Analogue inputs with thermal element
  • Analogue inputs with light and temperature
2 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard E33
Error
4 analogue inputs
(resolution: 12 Bit)
0...3.0 V - standard E3333
Error
2 analogue inputs
(resolution: 12 Bit)
Select the number of inputs for the
respective input configuration:

(1)   0...20 mA
(2)   4...20 mA
(3)   0...3.0 V
(4)   0.5...4.5 V / 0...5.0 V
(5)   0...10.0 V / 1.0...6.0 V
(6)   0...12.0 V
(7)   0...24.0 V
(8)   0...36.0 V
(9)   0...48.0 V
Exx
Error
4 analogue inputs
(resolution: 12 Bit)
Exxxx
Error

4. Would you like to expand the memory capacity of your MSR145 to over 1 billion measured values?

Please order the expansion slot for plugging-in a standard microSD card here. Item no.
Expansion slot for microSD card (available only for design housing B7 and B8)

Please note that:
  • this expansion slot with plugged-in microSD card only meets the protection category IP60,
    even with the design housing B8,
  • the expansion slot is not available in combination with light or thermal element,
  • the expansion slot is not available in combination with a multiple selection of sensors of the same measurand,
  • one formatted and ready for use microSD card (≥4GB) is included.
N10006
Error

5. General technical data on the MSR145.

Memory capacity: Over 2 000 000 measured values – expandable to over 1bn.
Key: Set bookmark or start and stop recording.
LED:  
blue:
red:
yellow:
Record indicator
Alarm indicator
Battery charge indicator
Power supply:
  • Lithium-polymer battery, 230 mAh or 900 mAh.
  • The battery is charged via the USB connection.
  • One battery charge is sufficient for operation of the unit for up to two years, depending on the battery and the measurement rate.
Options: Charging station (USB hub) for 7 MSR145 (item number B47002)
Interface: USB
PC software: Free Setup, Reader, Viewer and Online software (Windows 7/8/10) to record and evaluate data. All measurement parameters can be rapidly transferred to a PC via USB connection both during the measurement operation and once the measurement task has been completed. Thanks to the integrated clock (RTC), data from as many MSR145 units as required can be synchronised and merged into a single data record.
Operating conditions:
Temperature: -20...+65 °C
Optimum storage conditions:
Temperature:
Humidity:
+5...+45 °C (ideal storage conditions for the battery)
10...95 % relative humidity, non-condensing
Standards: The MSR145 complies with EU-Directives RoHS / WEEE.

Your selection:

Price:
Item no.:

MSR145 Multifunctional Data Recorder Specifications

Measured Parameters Temperature
Relative Humidity (RH) with Integrated Temp
Air Pressure
Fluid Pressure
3-Axis Acceleration (ie. Determining Position)
Light
2 or 4 Analog Inputs (0 to 3.0 Volts, 12-bit) - Standard
Note: Additional Ranges Available
0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V
Acceleration Range: ±15g @ -20°C to 65°C
Accuracy: ±0.15G @ 25°C
Resolution: 4mg
Response Time: 4mg
Temperature Range (Internal): -20°C to 65°C
Range (External): -10°C to 58°C; -55°C to 125°C; 0 to 1024°C (External Type K TC Connectors)
Accuracy (Internal): ±0.5°C
Accuracy (External): ±0.1°C (5°C to 45°C); ±0.2°C (-10°C to 58°C); ±0.5°C (-10°C to 65°C), ±2.0°C (-55°C to 125°C)
Resolution: 0.034°C
Response Time: Approximately 30 Seconds
Humidity Range: 0 to 100% RH, -20°C to 65°C
Accuracy: ±2% (10 to 85% RH, 0°C to 40°C); ±4% (85 to 95% RH, 0°C to 40°C)
Air Pressure Range: 0 to 2000 mbar Absolute or 0 to 14 Bar Absolute
Accuracy: ±2.5mbar (750 to 1100 mbar Absolute, 25°C); ±50 mbar (1-10 bar Absolute, 25°C)
Resolution: 15 Bit
Response Time: Approximately 1/10 Second
Fluid Pressure Range: 0 to 3000 mbar Absolute or 0 to 30 Bar Absolute
Accuracy: ±30mbar; ±300 mbar
Resolution: 15 Bit
Response Time: Approximately 1/10 Second
Light Range: 0 to 65,000 lx
Accuracy: 100 to 65,000 lx, Max ±5% Linearity Error, Max Sensitivity at 500 nm
Resolution: 4 lx
Analog Input Number: 2 or 4 (Each Channel Configured for Separate Ranges)
Range: 0 to 3.0 Volts (Standard)**
Resolution: 12 Bits
Note: Additional Ranges Available
0 to 20mA, 4 to 20mA, 0.5V to 4.5V, 0 to 5V, 1V to 6V, 0 to 10V, 0 to 12V and 0 to 24V
Sampling Rate Temperature & Humidity: 1/s to 12 Hours
Pressure: 10/s to every 12 Hours
Acceleration and Analog Input: 50/s to 12 Hours
Light Level: 1/s to 12 Hours
Analog: 50/s to 12 Hours
Data Storage Capacity Internal Storage: Approximately 2 Million Total Readings
External SD Card: Approximately 1 Billion Total Readings
Operating Mode Push Button Start/Stop
Storage Conditions Temperature: 5°C to 45°C
Humidity: 10 to 95% RH, non-condensing
LEDs Blue: Recording Indicator
Red: Alarm Indicator
Yellow: Battery Charge Indicator
Power Supply Rechargeable Lithium Polymer Battery (260mAh or 900mAh)
(USB Connection to PC recharges unit)
Battery Life 2-3 Months (Sampling Rate: 1 Minute)
Dimensions Standard Version: 20mm x 15mm x 52mm
Waterproof Version (Silicon Tube): 18mm x 14mm x 62mm
Standard Waterproof Version: 20mm x 15mm x 61mm
Weight Standard Version: 16 grams
Waterproof Version: 18 grams
Standard Waterproof Version: 23 grams
Enclosure Standard Version: Poly Carbonate, Non-Moulded
Waterproof Version: Silicon, Moulded
Standard Waterproof Version: Poly Carbonate, Moulded
Media Standard Version: Air
Waterproof Version: Air, Various Liquids
Standard Waterproof Version: Air, Water
Standards Compliance RoHS/WEEE, IP60 (Standard Version), IP67 (Waterproof Versions)
Software Compatible Windows 10, 8, 7, Vista and XP
Software Downloads
zip
(Size: 194.44 MB)
Version 6.03.02 Includes ShockViewer Add-On for MSR165 and MSR175.
User Manuals and Product Guides
pdf
(Size: 3.05 MB)
Write Your Own Review
You're reviewing:MSR145 Miniature Signal Data Recorder
Your Rating
Customer Questions
Can one of the analog inputs be used as a trigger to capture acceleration events? For example, record 5 seconds before the trigger (falling and/or rising voltage) to 5 seconds after the trigger event?

Yes, this meets the requirements of the VFC.  All of our vaccine monitoring loggers meet their requirements. 

This particular logger has audible alarm.  

Did you find what you were looking for?
Copyright © 2022 MicroDAQ, LLC. All Rights Reserved.