You can select various internal sensors as well as up to five external sensors or connectors.
Measured parameter / Measurement/ storage rate
Technical data
Internal
External (according to cable length)
0.20 m
1.00 m
1.60 m
Temperature 1/s to every 12 h
Working range: external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±0.1 °C (-25...+55 °C) ±0.3 °C (-40...+125 °C)
Item no. T9
Error
select
Item no. FT9/020
Error
1 2 3 4 5
select
Item no. FT9/100
Error
1 2 3 4 5
select
Item no. FT9/160
Error
1 2 3 4 5
select
Working range: -55...+125 °C Max. deviation: ±0.5 °C (10...+70 °C) ±2 °C (-55...+125 °C)
only available externally
Item no. FT2/020
Error
1 2 3 4 5
select
Item no. FT2/100
Error
1 2 3 4 5
select
Item no. FT2/160
Error
1 2 3 4 5
select
Connector for thermal element of Type K (without sensor) 1/s to every 12 h
Working range: -200...+1350 °C
only available externally
Item no. FT3/020
Error
1 2 3 4 5
select
Item no. FT3/100
Error
1 2 3 4 5
select
Item no. FT3/160
Error
1 2 3 4 5
select
Humidity with integrated temperature 1/s to every 12 h
Working range: 0...100 % rel. humidity external: -40...+125 °C internal: -20...+65 °C Max. deviation: ±2 % rel. humidity (10...80 %, +25 °C) ±3 % rel. humidity (80...100 %, +25 °C)
Item no. H3
Error
select
Item no. FH3/020
Error
1 2 3 4 5
select
Item no. FH3/100
Error
1 2 3 4 5
select
Item no. FH3/160
Error
1 2 3 4 5
select
Air pressure absolute, with integrated temperature 1/s to every 12 h
Working range: 10...2000 mbar absolute external: -40...+85 °C internal: -20...+65 °C Max. deviation: ±2 mbar (750...1100 mbar absolute, +25 °C)
Item no. P5
Error
select
Item no. FP10/020
Error
1 2 3 4 5
select
Item no. FP10/100
Error
1 2 3 4 5
select
Item no. FP10/160
Error
1 2 3 4 5
select
Working range: 0...14 bar absolute -20...+65 °C Max. deviation: ±50 mbar (1...10 bar abs., +25 °C)
only available externally
Item no. FP7/020
Error
1 2 3 4 5
select
Item no. FP7/100
Error
1 2 3 4 5
select
Item no. FP7/160
Error
1 2 3 4 5
select
Fluid pressure with integrated temperature 1/s to every 12 h Material in contact with media:Stainless Steel AISI 316L (DIN 1.4404 / 1.4435) O-rings: Viton® 70° Shore
Working range: -1000...3000 mbar rel. -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP9/020
Error
1 2 3 4 5
select
Item no. FP9/100
Error
1 2 3 4 5
select
Item no. FP9/160
Error
1 2 3 4 5
select
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS)
only available externally
Item no. FP3/020
Error
1 2 3 4 5
select
Item no. FP3/100
Error
1 2 3 4 5
select
Item no. FP3/160
Error
1 2 3 4 5
select
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS)
only available externally
Item no. FP4/020
Error
1 2 3 4 5
select
Item no. FP4/100
Error
1 2 3 4 5
select
Item no. FP4/160
Error
1 2 3 4 5
select
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS)
only available externally
Item no. FP8/020
Error
1 2 3 4 5
select
Item no. FP8/100
Error
1 2 3 4 5
select
Item no. FP8/160
Error
1 2 3 4 5
select
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS)
only available externally
Item no. FP12/020
Error
1 2 3 4 5
select
Item no. FP12/100
Error
1 2 3 4 5
select
Item no. FP12/160
Error
1 2 3 4 5
select
3-axis-acceleration (static) 1/s to every 12 h
Working range: -15...+15 g -20...+65 °C Max. deviation: ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C)
Item no. A
Error
select
Item no. FA/020
Error
select
Item no. FA/100
Error
select
Item no. FA/160
Error
select
Light 1/s to every 12 h
Working range: 0...83 000 lx Max. sensitivity at 550 nm
Item no. L3
Error
select
Item no. FL3/020
Error
1 2 3 4 5
select
Item no. FL3/100
Error
1 2 3 4 5
select
Item no. FL3/160
Error
1 2 3 4 5
select
Connection for strain gauges
Characteristics:full bridge rated output 1 mV/V bridge voltage 3 V
only available externally
Item no. FD/020
Error
1 2 3 4 5
select
Item no. FD/100
Error
1 2 3 4 5
select
Item no. FD/160
Error
1 2 3 4 5
select
Analogue inputs (resolution: 12 bit) 1/s to every 12 h
Input configuration:
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
only available externally
Exxxx/020
Error
select
Exxxx/100
Error
select
Exxxx/160
Error
select
Input configuration:
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
Please select! (1) 0...20 mA (2) 4...20 mA (3) 0...3.0 V (4) 0...5.0 V (5) 0...10.0 V (6) 0...12.0 V (7) 0...24.0 V (8) 0...36.0 V (9) 0...48.0 V
only available externally
Exxxx/020
Error
select
Exxxx/100
Error
select
Exxxx/160
Error
select
Control terminal
Characteristics:
Alarm output
Input for starting and stopping data recording
3 V voltage output
only available externally
Item no. FY/020
Error
select
Item no. FY/100
Error
select
Item no. FY/160
Error
select
FlexConnector (only combined with B22 and B23 cases)
The appropriate FlexSensors are below presented for choice.
only available externally
Item no. FX/020
Error
select
Item no. FX/100
Error
select
Item no. FX/160
Error
select
If you have selected a FlexConnector or already own an MSR145W2D data logger with a FlexConnector, you can order suitable sensors here. Please note only one interchangeable FlexSensor can be connected to the FlexConnector at a time.
Measured parameter / Measurement/ storage rate
Technical data
Item no.
Temperature 1/s to every 12 h
Working range: -40...+125 °C Max. deviation: ±0.1 °C (-25...+55 °C) ±0.3 °C (-40...+125 °C)
FXT9/160
Error
select
Humidity with integrated temperature 1/s to every 12 h
Working range: 0...100 % rel. humidity -40...+125 °C Max. deviation: ±2 % rel. humidity (10...80 %, +25 °C) ±3 % rel. humidity (80...100 %, +25 °C)
FXH3/160
Error
select
Fluid pressure with integrated temperature 1/s to every 12 h Material in contact with media:Stainless Steel AISI 316L (DIN 1.4404 / 1.4435) O-rings: Viton® 70° Shore
Working range: -1000...3000 mbar relative -20...+85 °C Max. deviation: ±30 mbar (1% FS)
FXP9/160
Error
select
Working range: 0...3000 mbar absolute -20...+85 °C Max. deviation: ±30 mbar (1% FS)
FXP3/160
Error
select
Working range: 0...30 bar absolute -20...+85 °C Max. deviation: ±0.3 bar (1% FS)
FXP4/160
Error
select
Working range: 0...400 bar absolute -20...+85 °C Max. deviation: ±4 bar (1% FS)
FXP8/160
Error
select
Working range: 0...1000 bar absolute -20...+85 °C Max. deviation: ±10 bar (1% FS)
FXP12/160
Error
select
3-axis-acceleration with Fast Peak (800 Hz) 1/s to every 12 h
Working range: -15...+15 g -20...+65 °C Max. deviation: ±0.15 g (0...5 g, +25 °C) ±0.25 g (5...10 g, +25 °C) ±0.45 g (10...15 g, +25 °C)
FXA4/160
Error
select
Light 1/s to every 12 h
Working range: 0...83 000 lx Max. sensitivity at 550 nm
FXL3/160
Error
select
A router will be needed if your MSR145W2D device is incorporated into a separate WiFi network or if measurement data is to be sent to MSR SmartCloud via a mobile network.
The cloud solution managed by MSR Electronics GmbH records data measured by MSR data loggers in a database. Through online access to MSR SmartCloud you are able to gain insight into your measured data, manage it, and create alert messages. When ordering the MSR145W2D data logger you will automatically receive the access code to MSR SmartCloud.