**Open Box** Indoor Air Quality Meter w/ SD Card Slot for Data Logging Kit
SKU
R9910SD-KIT--U--
$899.00
- Simultaneously Measure Readings from 3 Separate Probes (Temp/RH, CO2, CO or O2)
- Recorded Data Logs to SD Card with Easy Analysis Using Microsoft® Excel®
- 2 Seconds to 8 Hour User-Selectable Sampling Rate
- LCD Display Shows Current Readings, Max and Min Readings, Alarm and Battery Status
- 35 Hrs to 120 Hrs of Typical Battery Life (Dependant Upon Environment, Display and Sampling Rate)
Kit includes Temp/RH, CO2, CO and O2 Sensors, 16GB SD Card, AC Power Adapter, Hard Carrying Case & (6) AA Batteries
Limited Quantity - 1 Available
Reed Instruments R9910SD-KIT Air Quality Meter and Data Logger Specifications
External Inputs | (1) Temperature/Humidity Channel (1) Carbon Dioxide (CO2) (1) Carbon Monoxide (CO) or Oxygen (O2) |
Temperature | Range: -0°C to 50°C (32°F to 122°F) Accuracy: ±0.8°C (±1.5°F) Resolution: 0.1°C (0.1°F) Sensor Response Time: < 5 Seconds to 85% Full Value |
Humidity | Range: 5% RH to 95% RH Accuracy: ±3% Rdg + 1% RH (>70%); ±3%RH (<70%) Resolution: 0.1% Sensor Response Time: <5 Seconds to 85% Full Value |
Carbon Dioxide | Range: 0 to 4000 ppm Accuracy: ±40 ppm (<1000 ppm); ±5% (>1000 ppm) Resolution: 1 ppm Sensor Response Time: < 2 Minutes to 63% Full Value* * Dependent Upon Ambient Air Circulation |
Carbon Monoxide | Range: 0 to 1000 ppm Accuracy: ±(5.0% + 2ppm) Resolution: 1 ppm Sensor Response Time: < 30 Seconds |
Oxygen | Range: 0 to 30% Accuracy: ±(1.0% + 0.2%) Resolution: 0.1% Sensor Response Time: < 15 Seconds |
Data Storage Capacity | 1GB to 16GB onto External SD Card (Sold Separately) |
Sampling Rate | 2 Second to 8 Hours |
LCD Display | Type: Backlight Size: 52mm x 38mm (2.04" x 1.49") |
Download Time | Dependent Upon Size of SD Card |
Alarm | Audible Sound when Oxygen (O2) < 18.0% |
Power Source | Battery: (6) 1.5 Volt Heavy Duty AA Alkaline AC/DC Power: Optional 9 Volt Adapter (RSD-ADP-NA) |
Battery Life | Without LCD and SD Card: 120 Hours on Average With LCD and SD Card: 35 Hours |
Battery Classification | Dry Battery, Non-Hazardous |
Case Material | ABS Plastic |
Operating Range | Temperature: 0°C to 50°C (32°F to 122°F) Humidity: < 85% RH |
Standards Compliance | IP63 (Meter); IP60 (Sensors); CE |
Weight | 1.64 kgrams (3.61 lbs) - Complete Kit |
Dimensions | Meter: 177mm x 68mm x 45mm (6.9" x 2.6" x 1.7") Temp/RH Sensor: 197mm (7.75") CO2 Sensor: 150mm x 38mm x 28mm (5.9" x 1.5 " x 1.1") CO Sensor: 150mm x 38mm x 38mm (5.9" x 1.5 " x 1.5") O2 Sensor: 150mm x 38mm x 38mm (5.9" x 1.5" x 1.5") |