R9905 Data Logging Indoor Air Quality Meter

SKU
R9905
In Stock
$449.10
  • Measure and Record Temperature, Humidity and Carbon Dioxide
  • Recorded Data to Internal Memory with Easy Analysis Using Microsoft® Excel®
  • 1 Second to 60 Minute User-Selectable Sampling Rate
  • LCD Display Shows Current Readings, Max and Min Readings, Alarm and Battery Status
  • 10 Hours of Typical Battery Life (Dependant Upon Environment, Display and Sampling Rate)
  • Powered by 9-Volt Alkaline User-Replaceable Batteries
  • Available with Carbon Dioxide (CO2), Temperature and Humidity Calibration

Includes Temperature, Humidity and Carbon Dioxide Sensors, USB Cable, Hard Carrying Case and 9-Volt Battery

Overview of the Reed Instruments R9905 Data Logging Indoor Air Quality Meter

The Reed R9905 Data Logging Indoor Air Quality Meter measures carbon dioxide (CO2), temperature, humidity, and automatically calculates time-weighted average (TWA) and short-term exposure limit (STEL). This Indoor Air Quality (IAQ) meter features a nondispersive infrared (NDIR) CO2 sensor for stable, accurate readings and the option to track live measurements via the included software.

R9905 Air Quality Meter and Data Logger Specifications

External Inputs (1) Temperature/Humidity Channel
(1) Carbon Dioxide (CO2)
Carbon Dioxide Sensor Type: Nondispersive Infrared (NDIR)
Measurement Range: 0 to 30,000 ppm
Accuracy (0 to 5,000 ppm): ±(75 ppm + 3% of Reading)
Accuracy (5,001 to 30,000 ppm): ±(150 ppm + 5% of Reading)
Resolution: 1 ppm
Warm-Up Time: 20 Seconds
Sampling Rate: 2 Seconds
Humidity Range: 0% to 100% RH
Accuracy (10% to 90% RH): ±3% RH
Accuracy (Other Ranges): ±5% RH
Resolution: 0.1% RH
Sensor Response Time: <5 Seconds to 85% Full Value
Temperature Range: -20°C to 60°C (-4°F to 140°F)
Accuracy: ±0.8°C (±1.5°F)
Resolution: 0.1°C (0.1°F)
Sensor Response Time: < 5 Seconds to 85% Full Value
Data Storage Capacity 32,000 Readings
Sampling Rate 1 Second to 1 Hour
LCD Display Type: Backlight
Features: Data Hold, Min, Max, Average, Low Battery Indicator and Auto Shut-Off
Alarm Audible, Low and High Settings
Power Source Battery: 9 Volt Alkaline
Battery Life 10 Hours Continuous Use
Battery Classification Dry Battery, Non-Hazardous
Case Material ABS Plastic
Storage Range Temperature: -20°C to 60°C (-4°F to 140°F)
Humidity: 10 to 75% RH
Operating Range Temperature: 0°C to 50°C (32°F to 122°F)
Humidity: 0 to 90% RH
Standards Compliance CE
Weight 304 g (10.7 oz)
Dimensions Meter: 284mm x 65mm x 39mm (11.2" x 2.6" x 1.5")
Customer Questions