True RMS AC/DC Clamp Meter w/ Current Probe and NIST Calibration Certificate Kit

SKU
R5055-KIT-NIST
Special Order
$439.00
  • Measures AC/DC Current and Voltage, Resistance, Frequency, Capacitance, Duty Cycle and Contact Temperature
  • Up to 1000V and 1000A in Both AC/DC Modes
  • Built-in Non-Contact Voltage Detector and LED Flashlight
  • Low Pass Filter and Low Impedance (LoZ) Modes
  • 6000 Count Backlit LCD Display with Analog Bargraph
  • 18" Flexible Current Probe with Measurement up to 3000 Amps AC

Kit Includes R5055 Digital Clamp Meter, R5065 18" Flexible Current Probe, Type K Thermocouple, Test Leads, Carrying Case, (3) AAA Batteries and NIST Calibration Certificate

Special order - please allow 10-15 business days for this item to ship.
 

Reed Instruments R5055-KIT-NIST 1000Amp True RMS Digital Clamp Meter Specifications

AC/DC Current Measurement Range: 60, 600, 1000A
Accuracy: ±(2% of Reading + 5 Digits)
Resolution: 0.01, 0.1, 1A
AC/DC Current Measurement Range (AC): 6, 60, 600, 1000 Volts
Measurement Range (DC): 600 mVolt, 6, 60, 600, 1000 Volts
Accuracy (AC): ±(1.0% of Reading + 8 Digits)
Accuracy (DC): ±(0.5% of Reading + 5 Digits)
Resolution: 0.1 mVolt, 0.001 Volt, 0.01 Volt, 0.1 Volt, 1 Volt
Resistance Measurement Range: 600Ω, 6, 60, 600kΩ, 6, 60MΩ
Accuracy: ±(1.0% of Reading + 2 Digits)
Resolution: 0.1Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ
Capacitance Measurement Range: 60, 600.0nF, 6, 60, 600μF, 6, 60mF
Accuracy: ±(4.0% of Reading + 5 Digits)
Resolution: 0.01nF, 0.1nF, 0.001μF, 0.01μF, 0.1μF, 0.001mF, 0.01mF
Frequency Measurement Range: 10Hz, 1MHz
Accuracy: ±(0.1% of Reading + 3 Digits)
Resolution: 0.01Hz, 1kHz
Low Pass Filter (LPF) AC Voltage Measurement Range: 600 Volts, 1000 Volts
Accuracy: ±(2.0% of Reading + 5 Digits)
Resolution: 0.1 Volt, 1 Volt
Low Impedance (LoZ) AC Voltage Measurement Range: 600 Volts, 1000 Volts
Accuracy: ±(2.0% of Reading + 5 Digits)
Resolution: 0.1 Volt, 1 Volt
Temperature Measurement Range: -40°C to 1000°C (-40°F to 1832°F)
Accuracy: ±(1.0% of Reading + 2.0C (4.0°F))
Resolution: 1.0°C (1.0°F)
Display 6000 Count Backlit LCD
Features: Min, Max, Auto Shut Off (After 15 Minutes), Display Hold, Peak Hold, Zero Push Button Adjustment
Features Peak Hold, Relative Mode, Diode Test, Duty Cycle, Non-Contact Voltage Detector, Built-in Flashlight, Low Battery Indicator, Overrange Indicator
Analog Bargraph 31-Segment
Continuity Check Audible Signal if Resistance ≤30Ω
Range Selection Autoranging/Manual
Jaw Opening 42mm (1.7") up to 1500 MCM
Power Supply (3) AAA Batteries
Operating Environment Temperature: 0°C to 50°C (32°F to 122°F)
Humidity: 10% to 80% RH
Storage Environment Temperature: -10°C to 60°C (14°F to 140°F)
Humidity: 10% to 80% RH
Overvoltage Category CAT III 1000 Volts, CAT IV 600 Volts
Standards Compliance CE, ETL
Weight 447 grams (15.8 oz.)
Dimensions 27.2cm x 8.1cm x 4.35cm (10.7" x 3.2" x 1.7")

Reed Instruments R5065 3000A Flexible 18" Current Probe Specifications

AC Current Measurement Range: 30 Amps, 300Amps, 3000 Amps
Accuracy: ±(3.0% of Reading + 5 Digit)
Resolution: 0.1 Amps, 1 Amps, 10 Amps
Frequency Response 45Hz to 500Hz
Heating Time Approx. 30 to Maximum
Cooling Time Approx. 30 to 100°C (122°F)
Aperture Diameter 58mm (2.28")
Power Supply (3) AAA Batteries
Operating Environment Temperature: 0°C to 50°C (32°F to 122°F)
Humidity: 15 to 80% RH
Storage Environment Temperature: -20°C to 60°C (-4°F to 140°F)
Humidity: 15 to 80% RH
Overvoltage Category CAT IV 600 Voltage
Standards Compliance CE, ETL
Weight 260 grams (9.2 oz)
Dimensions 26.7cm x 11.94cm x 3.4cm (10.5" x 4.7" x 1.3")
Jaw Opening: 45.72 cm (18.0")
Cable Length: 99.1 cm (39.0")
Customer Questions
No Questions
Please, mind that only logged in users can submit questions