True RMS AC/DC Clamp Meter w/ Current Probe and NIST Calibration Certificate Kit
SKU
R5055-KIT-NIST
Special Order
$439.00
- Measures AC/DC Current and Voltage, Resistance, Frequency, Capacitance, Duty Cycle and Contact Temperature
- Up to 1000V and 1000A in Both AC/DC Modes
- Built-in Non-Contact Voltage Detector and LED Flashlight
- Low Pass Filter and Low Impedance (LoZ) Modes
- 6000 Count Backlit LCD Display with Analog Bargraph
- 18" Flexible Current Probe with Measurement up to 3000 Amps AC
Kit Includes R5055 Digital Clamp Meter, R5065 18" Flexible Current Probe, Type K Thermocouple, Test Leads, Carrying Case, (3) AAA Batteries and NIST Calibration Certificate
Special order - please allow 10-15 business days for this item to ship.
Reed Instruments R5055-KIT-NIST 1000Amp True RMS Digital Clamp Meter Specifications
| AC/DC Current | Measurement Range: 60, 600, 1000A Accuracy: ±(2% of Reading + 5 Digits) Resolution: 0.01, 0.1, 1A |
| AC/DC Current | Measurement Range (AC): 6, 60, 600, 1000 Volts Measurement Range (DC): 600 mVolt, 6, 60, 600, 1000 Volts Accuracy (AC): ±(1.0% of Reading + 8 Digits) Accuracy (DC): ±(0.5% of Reading + 5 Digits) Resolution: 0.1 mVolt, 0.001 Volt, 0.01 Volt, 0.1 Volt, 1 Volt |
| Resistance | Measurement Range: 600Ω, 6, 60, 600kΩ, 6, 60MΩ Accuracy: ±(1.0% of Reading + 2 Digits) Resolution: 0.1Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ |
| Capacitance | Measurement Range: 60, 600.0nF, 6, 60, 600μF, 6, 60mF Accuracy: ±(4.0% of Reading + 5 Digits) Resolution: 0.01nF, 0.1nF, 0.001μF, 0.01μF, 0.1μF, 0.001mF, 0.01mF |
| Frequency | Measurement Range: 10Hz, 1MHz Accuracy: ±(0.1% of Reading + 3 Digits) Resolution: 0.01Hz, 1kHz |
| Low Pass Filter (LPF) AC Voltage | Measurement Range: 600 Volts, 1000 Volts Accuracy: ±(2.0% of Reading + 5 Digits) Resolution: 0.1 Volt, 1 Volt |
| Low Impedance (LoZ) AC Voltage | Measurement Range: 600 Volts, 1000 Volts Accuracy: ±(2.0% of Reading + 5 Digits) Resolution: 0.1 Volt, 1 Volt |
| Temperature | Measurement Range: -40°C to 1000°C (-40°F to 1832°F) Accuracy: ±(1.0% of Reading + 2.0C (4.0°F)) Resolution: 1.0°C (1.0°F) |
| Display | 6000 Count Backlit LCD Features: Min, Max, Auto Shut Off (After 15 Minutes), Display Hold, Peak Hold, Zero Push Button Adjustment |
| Features | Peak Hold, Relative Mode, Diode Test, Duty Cycle, Non-Contact Voltage Detector, Built-in Flashlight, Low Battery Indicator, Overrange Indicator |
| Analog Bargraph | 31-Segment |
| Continuity Check | Audible Signal if Resistance ≤30Ω |
| Range Selection | Autoranging/Manual |
| Jaw Opening | 42mm (1.7") up to 1500 MCM |
| Power Supply | (3) AAA Batteries |
| Operating Environment | Temperature: 0°C to 50°C (32°F to 122°F) Humidity: 10% to 80% RH |
| Storage Environment | Temperature: -10°C to 60°C (14°F to 140°F) Humidity: 10% to 80% RH |
| Overvoltage Category | CAT III 1000 Volts, CAT IV 600 Volts |
| Standards Compliance | CE, ETL |
| Weight | 447 grams (15.8 oz.) |
| Dimensions | 27.2cm x 8.1cm x 4.35cm (10.7" x 3.2" x 1.7") |
Reed Instruments R5065 3000A Flexible 18" Current Probe Specifications
| AC Current | Measurement Range: 30 Amps, 300Amps, 3000 Amps Accuracy: ±(3.0% of Reading + 5 Digit) Resolution: 0.1 Amps, 1 Amps, 10 Amps |
| Frequency Response | 45Hz to 500Hz |
| Heating Time | Approx. 30 to Maximum |
| Cooling Time | Approx. 30 to 100°C (122°F) |
| Aperture Diameter | 58mm (2.28") |
| Power Supply | (3) AAA Batteries |
| Operating Environment | Temperature: 0°C to 50°C (32°F to 122°F) Humidity: 15 to 80% RH |
| Storage Environment | Temperature: -20°C to 60°C (-4°F to 140°F) Humidity: 15 to 80% RH |
| Overvoltage Category | CAT IV 600 Voltage |
| Standards Compliance | CE, ETL |
| Weight | 260 grams (9.2 oz) |
| Dimensions | 26.7cm x 11.94cm x 3.4cm (10.5" x 4.7" x 1.3") Jaw Opening: 45.72 cm (18.0") Cable Length: 99.1 cm (39.0") |