Multifunction Process Calibrator

SKU
R5850
Special Order
$2,845.00
  • Measures and Sources Volts, mA, RTDs, Thermocouples, Frequency and Ohms
  • Measures and Outputs 10 Types of RTDs and 12 Types of TC Signals
  • 0.02% Output and Measurement Accuracy
  • Performs Fast Linearity Tests with Auto Step and Auto Ramp Features
  • Easy to Read Screens Letting You View Input and Outpur Simultaneously
  • Rechargeable Ni-MH Battery, Low Battery Indicator, Auto Shut-Off 
  • Ability to Store Frequently Used Test Setups for Later Use

Includes Test Leads, Test Clips, Type K Thermocouple Wire Probe, USB Cable, Power Adapter and Carrying Case

Special order - please allow 7-10 business days for this item to ship.
 
User Manuals and Product Guides

Reed R5850 Multifunction Process Calibrator Specifications

DC Voltage Measurement Range: 50, 500mV, 30V (Upper Display), 50V (Lower Display)
Accuracy (50mV): ±(0.02% +10)
Accuracy (500mV): ±(0.02% +5)
Accuracy (30 Volts) - Upper Display: ±(0.02% +5)
Accuracy (50 Volts) - Lower Display: ±(0.02% +2)
Resolution: 0.001, 0.01, 1mV, 0.001V
DC Current Measurement Range: 20mA at 0 to 24mA
Accuracy: ±(0.02% +2)
Resolution: 0.001mA
Loop Current Measurement Range: 20mA (Loop) at 0 to 24mA
Accuracy: ±(0.02% +2)
Resolution: 0.001mA
Resistance Measurement Range: 500, 5000Ω
Accuracy: ±(0.02% +2)
Resolution: 0.01, 0.1Ω
Frequency Measurement Range: 100Hz, 1, 10, 100kHz
Accuracy: ±(0.01% +1)
Resolution: 0.01, 0.1, 1Hz
Type R Thermocouple Measurement Range: 0 to 1767°C (32 to 3212.6°F)
Accuracy (0 to 500°C): ±1.8°C (±3.24°F)
Accuracy (500 to 1767°C): ±1.5°C (±2.7°F)
Resolution: 1°C/°F
Type S Thermocouple Measurement Range: 0 to 1767°C (32 to 3212.6°F)
Accuracy (0 to 500°C): ±1.8°C (±3.24°F)
Accuracy (500 to 1767°C): ±1.5°C (±2.7°F)
Resolution: 1°C/°F
Type B Thermocouple Measurement Range: 600 to 1820°C (1112 to 3308°F)
Accuracy (600 to 800°C): ±2.2°C (±3.96°F)
Accuracy (800 to 1000°C): ±1.8°C (±3.24°F)
Accuracy (1000 to 1820°C): ±1.4°C (±2.52°F)
Resolution: 1°C/°F
Type E Thermocouple Measurement Range: -50 to 1000°C (-58 to 1832°F)
Accuracy (-50 to 0°C): ±0.9°C (±1.62°F)
Accuracy (0 to 1000°C): ±1.5°C (±2.7°F)
Resolution: 0.1°C/°F
Type K Thermocouple Measurement Range: -100 to 1372°C (-148 to 2501.6°F)
Accuracy (-100 to 0°C): ±1.2°C (±2.16°F)
Accuracy (0 to 1372°C): ±0.8°C (±1.44°F)
Resolution: 0.1°C/°F
Type J Thermocouple Measurement Range: -60 to 1200°C (-76 to 2192°F)
Accuracy (-60 to 0°C): ±1.0°C (±1.8°F)
Accuracy (0 to 1200°C): ±0.7°C (±1.26°F)
Resolution: 0.1°C/°F
Type T Thermocouple Measurement Range: -100 to 400°C (-148 to 752°F)
Accuracy (-100 to 0°C): ±1.0°C (±1.8°F)
Accuracy (0 to 400°C): ±0.7°C (±1.26°F)
Resolution: 0.1°C/°F
Type N Thermocouple Measurement Range: -200 to 1300°C (-328 to 2372°F)
Accuracy (-200 to 0°C): ±1.5°C (±2.7°F)
Accuracy (0 to 1300°C): ±0.9°C (±1.62°F)
Resolution: 0.1°C/°F
Type L Thermocouple Measurement Range: -200 to 900°C (-328 to 1652°F)
Accuracy (-200 to 0°C): ±0.85°C (±1.53°F)
Accuracy (0 to 900°C): ±0.7°C (±1.26°F)
Resolution: 0.1°C/°F
Type U Thermocouple Measurement Range: -200 to 400°C (-328 to 752°F)
Accuracy (-200 to 0°C): ±1.1°C (±1.98°F)
Accuracy (0 to 400°C): ±0.75°C (±1.35°F)
Resolution: 0.1°C/°F
Type XK Thermocouple Measurement Range: -200 to 800°C (-328 to 1472°F)
Accuracy (-200 to -100°C): ±0.5°C (±0.9°F)
Accuracy (-100 to 800°C): ±0.60°C (±1.08°F)
Resolution: 0.1°C/°F
Type BP Thermocouple Measurement Range: 0 to 2500°C (32 to 4532°F)
Accuracy (0 to 800°C): ±1.2°C (±2.16°F)
Accuracy (800 to 2500°C): ±2.5°C (±4.5°F)
Resolution: 0.1°C/°F
Pt100 (2-Wire/3-Wire) Measurement Range: -200 to 850°C (-328 to 1562°F)
Accuracy: ±0.4°C (±0.72°F)
Resolution: 0.1°C/°F
Pt100 (4-Wire) Measurement Range: -200 to 850°C (-328 to 1166°F)
Accuracy: ±0.3°C (±0.54°F)
Resolution: 0.1°C/°F
Pt200 (2-Wire/3-Wire) Measurement Range: -200 to 630°C (-328 to 1562°F)
Accuracy (-200 to 250°C): ±0.3°C (±0.54°F)
Accuracy (250 to 630°C): ±1.6°C (±2.88°F)
Resolution: 0.1°C/°F
Pt200 (4-Wire) Measurement Range: -200 to 630°C (-328 to 1166°F)
Accuracy (-200 to 250°C): ±0.2°C (±0.36°F)
Accuracy (250 to 630°C): ±0.8°C (±1.44°F)
Resolution: 0.1°C/°F
Pt500 (2-Wire/3-Wire) Measurement Range: -200 to 630°C (-328 to 1166°F)
Accuracy (-200 to 500°C): ±0.6°C (±1.08°F)
Accuracy (500 to 630°C): ±0.9°C (±1.62°F)
Resolution: 0.1°C/°F
Pt500 (4-Wire) Measurement Range: -200 to 630°C (-328 to 1166°F)
Accuracy (-200 to 500°C): ±0.3°C (±0.54°F)
Accuracy (250 to 630°C): ±0.4°C (±0.72°F)
Resolution: 0.1°C/°F
Pt1000 (2-Wire/3-Wire) Measurement Range: -200 to 650°C (-328 to 1202°F)
Accuracy: ±0.3°C (±0.54°F)
Resolution: 0.1°C/°F
Pt1000 (4-Wire) Measurement Range: -200 to 650°C (-328 to 1202°F)
Accuracy: ±0.15°C (±0.27°F)
Resolution: 0.1°C/°F
Cu10 Measurement Range: -100 to 260°C (-148 to 500°F)
Accuracy: ±1.80°C (±3.24°F)
Resolution: 0.1°C/°F
Cu50 (2-Wire/3-Wire) Measurement Range: -50 to 150°C (-58 to 302°F)
Accuracy: ±0.80°C (±1.44°F)
Resolution: 0.1°C/°F
Cu50 (4-Wire) Measurement Range: -50 to 150°C (-58 to 302°F)
Accuracy: ±0.5°C (±0.9°F)
Resolution: 0.1°C/°F
Cu100 (2-Wire/3-Wire) Measurement Range: -50 to 150°C (-58 to 302°F)
Accuracy: ±0.4°C (±0.72°F)
Resolution: 0.1°C/°F
Cu100 (4-Wire) Measurement Range: -50 to 150°C (-58 to 302°F)
Accuracy: ±0.25°C (±0.45°F)
Resolution: 0.1°C/°F
Pt100-392 (2-Wire/3-Wire) Measurement Range: -200 to 630°C (-328 to 1166°F)
Accuracy: ±0.5°C (±0.9°F)
Resolution: 0.1°C/°F
Pt100-392 (4-Wire) Measurement Range: -200 to 630°C (-328 to 1166°F)
Accuracy: ±0.3°C (±0.54°F)
Resolution: 0.1°C/°F
Pt100-JIS (2-Wire/3-Wire) Measurement Range: -200 to 630°C (-328 to 1166°F)
Accuracy: ±0.5°C (±0.9°F)
Resolution: 0.1°C/°F
Pt100-JIS (4-Wire) Measurement Range: -200 to 630°C (-328 to 1166°F)
Accuracy: ±0.3°C (±0.54°F)
Resolution: 0.1°C/°F
Ni120 (2-Wire/3-Wire) Measurement Range: -80 to 260°C (-112 to 500°F)
Accuracy: ±0.3°C (±0.54°F)
Resolution: 0.1°C/°F
Ni120 (4-Wire) Measurement Range: -80 to 260°C (-112 to 500°F)
Accuracy: ±0.2°C (±0.36°F)
Resolution: 0.1°C/°F
Source Function: DC Voltage Measurement Range: 100mV, 1 Volt, 10 Volts
Accuracy: ±(0.02% +10)
Resolution: 0.001, 0.01mV, 0.0001V
Source Function: DC Current Measurement Range: 20mA at 0 to 24mA; 20mA (SIM) at 0 to 24mA
Accuracy: ±(0.02% +2)
Resolution: 0.001mA
Source Function: Resistance Measurement Range: 400; 4000Ω; 40kΩ
Accuracy: ±(0.02% +8); ±(0.05% +10); ±(0.1% +40)
Resolution: 0.01; 0.1; 1Ω
Source Function: Frequency Measurement Range: 200; 2000Hz; 20; 100kHz
Accuracy: ±(0.01% +1); (±3 dgt.); 100kHz: ±5 dgt.
Resolution: 0.01; 0.1; 1; 10Hz
Source Function: Pulse Measurement Range: 100Hz; 1; 10kHz
Accuracy: ±2 dgt
Resolution: 1 cyc
Source Function: Switch Quantity Measurement Range: 100Hz; 1; 10; 100kHz
Accuracy: ±2 dgt
Resolution: 0.01; 0.1; 1; 10Hz
Ramp Functions Source Functions: Voltage, Current, Resistance, Frequency, Temperature
Ramps: Slow Ramp, Fast Ramp, 25% Step-Ramp
Loop Power Function Voltage: 24 Volts
Accuracy: 10%
Maximum Current: 22mA, Short Circuit Protected
Step Functions Source Functions: Voltage, Current, Resistance, Frequency, Temperature
Steps: 25% of Range, 100% of Range
Display 20,000 Count TFT Color LCD Display
Kick Stand Yes
Power Supply 1.2V x 6 AA Rechargeable Batteries
Internal Phase Shift Yes
Auto Shut-Off Yes
Low Battery Indicator Yes
Replaceable Test Leads Yes
Power Supply (6) 1.2 Volt AA Rechargeable Batteries
Maximum Operating Altitude 2000 Meters (6561 ft)
Operating Environment Temperature: -10°C to 55°C (14°F to 131°F)
Humidity: ≤95% RH (Non-Condensing)
Storage Environment Temperature: -20°C to 70°C (-4°F to 158°F)
Humidity: 10 to 90% RH (Non-Condensing)
Standards Compliance CE, RoHS
Weight 650 grams (22.92 oz)
Dimensions 195mm x 95mm x 58mm (7.7" x 3.7" x 2.3")
Customer Questions
No Questions
Please, mind that only logged in users can submit questions