Multifunction Process Calibrator
SKU
R5850
Special Order
$2,845.00
- Measures and Sources Volts, mA, RTDs, Thermocouples, Frequency and Ohms
- Measures and Outputs 10 Types of RTDs and 12 Types of TC Signals
- 0.02% Output and Measurement Accuracy
- Performs Fast Linearity Tests with Auto Step and Auto Ramp Features
- Easy to Read Screens Letting You View Input and Outpur Simultaneously
- Rechargeable Ni-MH Battery, Low Battery Indicator, Auto Shut-Off
- Ability to Store Frequently Used Test Setups for Later Use
Includes Test Leads, Test Clips, Type K Thermocouple Wire Probe, USB Cable, Power Adapter and Carrying Case
Special order - please allow 7-10 business days for this item to ship.
Reed R5850 Multifunction Process Calibrator Specifications
| DC Voltage | Measurement Range: 50, 500mV, 30V (Upper Display), 50V (Lower Display) Accuracy (50mV): ±(0.02% +10) Accuracy (500mV): ±(0.02% +5) Accuracy (30 Volts) - Upper Display: ±(0.02% +5) Accuracy (50 Volts) - Lower Display: ±(0.02% +2) Resolution: 0.001, 0.01, 1mV, 0.001V |
| DC Current | Measurement Range: 20mA at 0 to 24mA Accuracy: ±(0.02% +2) Resolution: 0.001mA |
| Loop Current | Measurement Range: 20mA (Loop) at 0 to 24mA Accuracy: ±(0.02% +2) Resolution: 0.001mA |
| Resistance | Measurement Range: 500, 5000Ω Accuracy: ±(0.02% +2) Resolution: 0.01, 0.1Ω |
| Frequency | Measurement Range: 100Hz, 1, 10, 100kHz Accuracy: ±(0.01% +1) Resolution: 0.01, 0.1, 1Hz |
| Type R Thermocouple | Measurement Range: 0 to 1767°C (32 to 3212.6°F) Accuracy (0 to 500°C): ±1.8°C (±3.24°F) Accuracy (500 to 1767°C): ±1.5°C (±2.7°F) Resolution: 1°C/°F |
| Type S Thermocouple | Measurement Range: 0 to 1767°C (32 to 3212.6°F) Accuracy (0 to 500°C): ±1.8°C (±3.24°F) Accuracy (500 to 1767°C): ±1.5°C (±2.7°F) Resolution: 1°C/°F |
| Type B Thermocouple | Measurement Range: 600 to 1820°C (1112 to 3308°F) Accuracy (600 to 800°C): ±2.2°C (±3.96°F) Accuracy (800 to 1000°C): ±1.8°C (±3.24°F) Accuracy (1000 to 1820°C): ±1.4°C (±2.52°F) Resolution: 1°C/°F |
| Type E Thermocouple | Measurement Range: -50 to 1000°C (-58 to 1832°F) Accuracy (-50 to 0°C): ±0.9°C (±1.62°F) Accuracy (0 to 1000°C): ±1.5°C (±2.7°F) Resolution: 0.1°C/°F |
| Type K Thermocouple | Measurement Range: -100 to 1372°C (-148 to 2501.6°F) Accuracy (-100 to 0°C): ±1.2°C (±2.16°F) Accuracy (0 to 1372°C): ±0.8°C (±1.44°F) Resolution: 0.1°C/°F |
| Type J Thermocouple | Measurement Range: -60 to 1200°C (-76 to 2192°F) Accuracy (-60 to 0°C): ±1.0°C (±1.8°F) Accuracy (0 to 1200°C): ±0.7°C (±1.26°F) Resolution: 0.1°C/°F |
| Type T Thermocouple | Measurement Range: -100 to 400°C (-148 to 752°F) Accuracy (-100 to 0°C): ±1.0°C (±1.8°F) Accuracy (0 to 400°C): ±0.7°C (±1.26°F) Resolution: 0.1°C/°F |
| Type N Thermocouple | Measurement Range: -200 to 1300°C (-328 to 2372°F) Accuracy (-200 to 0°C): ±1.5°C (±2.7°F) Accuracy (0 to 1300°C): ±0.9°C (±1.62°F) Resolution: 0.1°C/°F |
| Type L Thermocouple | Measurement Range: -200 to 900°C (-328 to 1652°F) Accuracy (-200 to 0°C): ±0.85°C (±1.53°F) Accuracy (0 to 900°C): ±0.7°C (±1.26°F) Resolution: 0.1°C/°F |
| Type U Thermocouple | Measurement Range: -200 to 400°C (-328 to 752°F) Accuracy (-200 to 0°C): ±1.1°C (±1.98°F) Accuracy (0 to 400°C): ±0.75°C (±1.35°F) Resolution: 0.1°C/°F |
| Type XK Thermocouple | Measurement Range: -200 to 800°C (-328 to 1472°F) Accuracy (-200 to -100°C): ±0.5°C (±0.9°F) Accuracy (-100 to 800°C): ±0.60°C (±1.08°F) Resolution: 0.1°C/°F |
| Type BP Thermocouple | Measurement Range: 0 to 2500°C (32 to 4532°F) Accuracy (0 to 800°C): ±1.2°C (±2.16°F) Accuracy (800 to 2500°C): ±2.5°C (±4.5°F) Resolution: 0.1°C/°F |
| Pt100 (2-Wire/3-Wire) | Measurement Range: -200 to 850°C (-328 to 1562°F) Accuracy: ±0.4°C (±0.72°F) Resolution: 0.1°C/°F |
| Pt100 (4-Wire) | Measurement Range: -200 to 850°C (-328 to 1166°F) Accuracy: ±0.3°C (±0.54°F) Resolution: 0.1°C/°F |
| Pt200 (2-Wire/3-Wire) | Measurement Range: -200 to 630°C (-328 to 1562°F) Accuracy (-200 to 250°C): ±0.3°C (±0.54°F) Accuracy (250 to 630°C): ±1.6°C (±2.88°F) Resolution: 0.1°C/°F |
| Pt200 (4-Wire) | Measurement Range: -200 to 630°C (-328 to 1166°F) Accuracy (-200 to 250°C): ±0.2°C (±0.36°F) Accuracy (250 to 630°C): ±0.8°C (±1.44°F) Resolution: 0.1°C/°F |
| Pt500 (2-Wire/3-Wire) | Measurement Range: -200 to 630°C (-328 to 1166°F) Accuracy (-200 to 500°C): ±0.6°C (±1.08°F) Accuracy (500 to 630°C): ±0.9°C (±1.62°F) Resolution: 0.1°C/°F |
| Pt500 (4-Wire) | Measurement Range: -200 to 630°C (-328 to 1166°F) Accuracy (-200 to 500°C): ±0.3°C (±0.54°F) Accuracy (250 to 630°C): ±0.4°C (±0.72°F) Resolution: 0.1°C/°F |
| Pt1000 (2-Wire/3-Wire) | Measurement Range: -200 to 650°C (-328 to 1202°F) Accuracy: ±0.3°C (±0.54°F) Resolution: 0.1°C/°F |
| Pt1000 (4-Wire) | Measurement Range: -200 to 650°C (-328 to 1202°F) Accuracy: ±0.15°C (±0.27°F) Resolution: 0.1°C/°F |
| Cu10 | Measurement Range: -100 to 260°C (-148 to 500°F) Accuracy: ±1.80°C (±3.24°F) Resolution: 0.1°C/°F |
| Cu50 (2-Wire/3-Wire) | Measurement Range: -50 to 150°C (-58 to 302°F) Accuracy: ±0.80°C (±1.44°F) Resolution: 0.1°C/°F |
| Cu50 (4-Wire) | Measurement Range: -50 to 150°C (-58 to 302°F) Accuracy: ±0.5°C (±0.9°F) Resolution: 0.1°C/°F |
| Cu100 (2-Wire/3-Wire) | Measurement Range: -50 to 150°C (-58 to 302°F) Accuracy: ±0.4°C (±0.72°F) Resolution: 0.1°C/°F |
| Cu100 (4-Wire) | Measurement Range: -50 to 150°C (-58 to 302°F) Accuracy: ±0.25°C (±0.45°F) Resolution: 0.1°C/°F |
| Pt100-392 (2-Wire/3-Wire) | Measurement Range: -200 to 630°C (-328 to 1166°F) Accuracy: ±0.5°C (±0.9°F) Resolution: 0.1°C/°F |
| Pt100-392 (4-Wire) | Measurement Range: -200 to 630°C (-328 to 1166°F) Accuracy: ±0.3°C (±0.54°F) Resolution: 0.1°C/°F |
| Pt100-JIS (2-Wire/3-Wire) | Measurement Range: -200 to 630°C (-328 to 1166°F) Accuracy: ±0.5°C (±0.9°F) Resolution: 0.1°C/°F |
| Pt100-JIS (4-Wire) | Measurement Range: -200 to 630°C (-328 to 1166°F) Accuracy: ±0.3°C (±0.54°F) Resolution: 0.1°C/°F |
| Ni120 (2-Wire/3-Wire) | Measurement Range: -80 to 260°C (-112 to 500°F) Accuracy: ±0.3°C (±0.54°F) Resolution: 0.1°C/°F |
| Ni120 (4-Wire) | Measurement Range: -80 to 260°C (-112 to 500°F) Accuracy: ±0.2°C (±0.36°F) Resolution: 0.1°C/°F |
| Source Function: DC Voltage | Measurement Range: 100mV, 1 Volt, 10 Volts Accuracy: ±(0.02% +10) Resolution: 0.001, 0.01mV, 0.0001V |
| Source Function: DC Current | Measurement Range: 20mA at 0 to 24mA; 20mA (SIM) at 0 to 24mA Accuracy: ±(0.02% +2) Resolution: 0.001mA |
| Source Function: Resistance | Measurement Range: 400; 4000Ω; 40kΩ Accuracy: ±(0.02% +8); ±(0.05% +10); ±(0.1% +40) Resolution: 0.01; 0.1; 1Ω |
| Source Function: Frequency | Measurement Range: 200; 2000Hz; 20; 100kHz Accuracy: ±(0.01% +1); (±3 dgt.); 100kHz: ±5 dgt. Resolution: 0.01; 0.1; 1; 10Hz |
| Source Function: Pulse | Measurement Range: 100Hz; 1; 10kHz Accuracy: ±2 dgt Resolution: 1 cyc |
| Source Function: Switch Quantity | Measurement Range: 100Hz; 1; 10; 100kHz Accuracy: ±2 dgt Resolution: 0.01; 0.1; 1; 10Hz |
| Ramp Functions | Source Functions: Voltage, Current, Resistance, Frequency, Temperature Ramps: Slow Ramp, Fast Ramp, 25% Step-Ramp |
| Loop Power Function | Voltage: 24 Volts Accuracy: 10% Maximum Current: 22mA, Short Circuit Protected |
| Step Functions | Source Functions: Voltage, Current, Resistance, Frequency, Temperature Steps: 25% of Range, 100% of Range |
| Display | 20,000 Count TFT Color LCD Display |
| Kick Stand | Yes |
| Power Supply | 1.2V x 6 AA Rechargeable Batteries |
| Internal Phase Shift | Yes |
| Auto Shut-Off | Yes |
| Low Battery Indicator | Yes |
| Replaceable Test Leads | Yes |
| Power Supply | (6) 1.2 Volt AA Rechargeable Batteries |
| Maximum Operating Altitude | 2000 Meters (6561 ft) |
| Operating Environment | Temperature: -10°C to 55°C (14°F to 131°F) Humidity: ≤95% RH (Non-Condensing) |
| Storage Environment | Temperature: -20°C to 70°C (-4°F to 158°F) Humidity: 10 to 90% RH (Non-Condensing) |
| Standards Compliance | CE, RoHS |
| Weight | 650 grams (22.92 oz) |
| Dimensions | 195mm x 95mm x 58mm (7.7" x 3.7" x 2.3") |
Customer Questions