Professional Clamp Meter Kit
SKU
R5075-KIT
Special Order
$559.00
- Measures AC/DC Current and Voltage, Resistance, Capacitance, Frequency and Contact Temperature
- Slim Jaw Design for Easy Access to Cables
- Dual Backlit LCD Display Shows Simultaneous Voltage and Current Measurements
- Low Battery Indicator, Audible and Visual Polarity Indicator Low Pass Filter and InRush Measurement Features
Kit Includes R5075 Clamp Meter and R5065 18" Flexible Current Probe
Special order - please allow 7-10 business days for this item to ship.
Reed Instruments R5075 Professional Clamp Meter Specifications
| AC/DC Current | Measurement Range: 999.9 Amps Accuracy (AC): ±(2.5% of Reading + 5 Digits) Accuracy (DC): ±(2.0% of Reading + 5 Digits) Resolution: 0.1A |
| AC/DC Voltage | Measurement Range (AC): 999.9 Volts, 1500 Volts Measurement Range (DC): 999.9 mV, 999.9 Volts, 2500 Volts Accuracy: ±(1.0% of Reading + 5 Digits) Resolution: 0.1 mV, 0.1 Volts; 1.0 Volts |
| Resistance | Measurement Range: 999.9Ω; 9.999KΩ; 99.99KΩ Accuracy: ±(1.0% of Reading + 5 Digits) Resolution: 0.1Ω; 0.001KΩ; 0.01KΩ |
| Capacitance | Measurement Range: 100µF; 1000µF; Accuracy:±(1.0% of Reading + 5 Digits) Resolution: 0.1µF; 1.0µF |
| Frequency | Measurement Range: 5.0Hz to 999.9Hz Accuracy: ±(0.5% of Reading + 5 Digits) Resolution: 0.1Hz |
| Low Pass Filter (LPF) AC Voltage | Measurement Range: 999.9V Accuracy: ±(2.0% of Reading + 9 Digits) Resolution: 0.1V |
| Low Pass Filter (LPF) AC Current | Measurement Range: 999.9A Accuracy: ±(2.5% of Reading + 9 Digits) Resolution: 0.1A |
| DC Power | Measurement Range (AC): 999.9kVA; 2500kVA Accuracy: ±(3.0% of Reading + 5 Digits) Accuracy (LPF): ±(4.0% of Reading + 9 Digits) Resolution: 0.01A; 0.1A; 1.0A |
| Flexible AC Current Probe (Using Optional R5065) |
Measurement Range (AC):30.0A; 300.0A; 3000.0A Accuracy: ±(2.0% of Reading + 20 Digits) Resolution: 0.1kVA; 1.0kVA |
| Temperature | Measurement Range: -40°C to 400°C (-40°F to 752°F) Accuracy (°C): ±1.0% of Reading + 30 Digits Accuracy (°F): ±1.0% of Reading + 60 Digits Resolution: 0.1°C (0.2°F) |
| Internal Memory | 999 Data Points |
| Low Pass Filter (LPF) | Yes |
| Inrush Measurement | Yes |
| True RMS | Yes |
| High Voltage Alarm | Yes |
| Overrange Indicator | Yes |
| Magnetic Hanging Strap Compatible | Yes with R5900 Magnetic Meter Strap |
| Flexible Current Probe Compatible | Yes with R5065 3000Amp Flexible 18" Current Probe |
| Display | Type: 9,999 Count Backlit LCD Features: Display Hold, Max, Min, Average, Peak Capturing, Zero Push Button Adjustment, Diode Test, Auto Shut Off (After 15 Minutes), Low Battery Indicator |
| Continuity Check | Audible and Visual Indicators if Resistance ≤30Ω |
| Power Supply | (2) AA Batteries |
| Jaw Opening | 35 mm (1.4") |
| Operating Environment | Temperature: 0°C to 50°C (32°F to 122°F) Humidity: 10% to 80% RH |
| Storage Environment | Temperature: -20°C to 60°C (-4°F to 140°F) Humidity: 10% to 80% RH |
| Standards Compliance | CE, ETL, RoHS, IP65, CAT III 1500 Volts, CT IV 600 Volts |
| Weight | 540 grams (19 oz) |
| Dimensions | 29.5cm x 7.3cm x 5.0cm (11.6" x 2.9" x 2.0") |
Reed Instruments R5065 3000A Flexible 18" Current Probe Specifications
| AC Current | Measurement Range: 30 Amps, 300Amps, 3000 Amps Accuracy: ±(3.0% of Reading + 5 Digit) Resolution: 0.1 Amps, 1 Amps, 10 Amps |
| Frequency Response | 45Hz to 500Hz |
| Heating Time | Approx. 30 to Maximum |
| Cooling Time | Approx. 30 to 100°C (122°F) |
| Aperture Diameter | 58mm (2.28") |
| Power Supply | (3) AAA Batteries |
| Operating Environment | Temperature: 0°C to 50°C (32°F to 122°F) Humidity: 15 to 80% RH |
| Storage Environment | Temperature: -20°C to 60°C (-4°F to 140°F) Humidity: 15 to 80% RH |
| Overvoltage Category | CAT IV 600 Voltage |
| Standards Compliance | CE, ETL |
| Weight | 260 grams (9.2 oz) |
| Dimensions | 26.7cm x 11.94cm x 3.4cm (10.5" x 4.7" x 1.3") Jaw Opening: 45.72 cm (18.0") Cable Length: 99.1 cm (39.0") |