Sentinel Monitoring System with No Enclosure

SKU
SCD-1200
Special Order
$615.00
  • 12 External Inputs Supporting 2K and 10K Thermistors, 4-20mA and Pulse Count
  • -85°C to 76°C Temperature Measurement Range
  • Ethernet Communications with Unlimited Storage on Sentinel Servers
  • Remotely Access via Web or App for Reporting, Setup and Configuration
  • Alarm Notifications Sent to Unlimited Number of Users via Text, Email or Phone Calls
  • LED Indicators for Power, Online and Activity
Special order - please allow 5-7 business days for this item to ship.
 
User Manuals and Product Guides

Sensaphone SCD-1200 Sentinel Monitoring System Specifications

Inputs Number: 12 Universal
NO / NC: Normally Open / Normally Closed Dry Contact
Type: 2.8K Thermistor, 10K Thermistor, 4-20mA Current Loop, Pulse Count
Resolution: 12 bits
Temperature Measurement Range: -85°C to 76°C (-109°F to 168°F)
Accuracy:
Output Relay Type: (1) Low Voltage NO/NC Relay Output
Alarm Switching: Manual or Automatic
Rated: 1 Amp 30 Volts AC/ 1 Amp 30 Volts DC
Programmable
Data Logging Storage: Unlimited Samples Securely Stored on Sentinel Servers
Sampling Interval: 1 Minute to 24 Hours
User Programmable Channel Selection
Remote Access Website or Mobile App to Access Status, Programming, Configuration, Settings
LED Indicators 12 LEDs for Alarm Status, Power Status, Online Status, Relay Output Status and Cellular Link
Alarm Notifications Unlimited Number of Email, Text or Phone Calls
Programmable Alarm Escalation Levels
Comprehensive Scheduling per Input, Profile and Alarm Destination
Unlimited Number of User Profiles
Multiple Contact Types per User
Communication Port Ethernet 10/100 Base-T
Power Supply AC Adapter: 90 to 260 Volts AC/7.5 Volts DC 50/60 Hz 7.5 Watt Wall Plug-in Transformer with 6 ft Cord (Included)
Power Consumption: 2.6 Watts
Power Protection: Metal Oxide Varistor/td>
Battery Backup 8-Hour 4.8 Volt 2000mAHr NiMh Rechargeable Battery Backup in the Event of a Power Outage
Operating Environment Temperature: 0°C to 50°C (32°F to 122°F)
Humidity: 0 to 90% RH, Non-Condensing
Storage Environment Temperature: 0°C to 50°C (32°F to 122°F)
Humidity: 0 to 90% RH, Non-Condensing
Enclosure Durable Powder Coated Metal Housing Suitable for Wall or Panel Installation or Weatherproof NEMA 4X Rated Fiberglass Enclosure
Standards Compliance FCC Part 15 Class A
Weight Metal Enclosure: 1.0 lbs (0.45 kg)
Weatherproof Enclosure: 3.7 lbs (1.67 kg)
Dimensions Metal Enclosure: 140mm x 160mm x 38mm (5.50" x 6.30" x 1.50")
Weatherproof Enclosure: 309mm x 260mm x 89mm (12.17" x 10.25" x 3.50")
Customer Questions
No Questions
Please, mind that only logged in users can submit questions