Voltage Current and Temperature Data Logger

SKU
VERSALOG-DCVC
Special Order
$549.00
  • 4 Input Channels for DC Voltage, 3 Input Channels for Current and 1 Internal Temperature Thermistor
  • 0 to 20V, 0 to 10V, 0 to 5V, 0 to 2V, 4-20mA and 0 to 50mA Measurement Options
  • 20 milliseconds to 12 hour Sampling Interval
  • Fast Sampling Mode, Alarm and Excitation Output
  • 10 Year Battery Life @ 1 Minute Sampling Rate
  • Stores up to 4 Million Recorded Readings onto Non-Volatile Memory
  • Excitation Control Output for Powering Connected Devices

Requires SiteView Software (Sold Separately)

Special order - please allow 5-7 business days for this item to ship
 
User Manuals and Product Guides
pdf
(Size: 0.68 MB)

Versalog VERSALOG-DCVC 8-Channel DC Voltage and Current Data Logger Specifications

Channels DC Voltage: 4
Current: 3
Temperature: 1
Voltage Measurement Range: 0 to 20 Volts; 0 to 10 Volts; 0 to 5 Volts; 0 to 2 Volts (Programmable)
Accuracy (0.1 V and Higher): ±0.15% @ 25°C
Accuracy (0 to 0.1 Volts): ±0.5% @ 25°C
Protection: -3 Volts DC ~ ±40 Volts DC
Current Measurement Range: 4 to 20 mA; 0 to 50mA (Programmable)
Accuracy (4-20 mA): ±0.15% FSR @ 25°C
Accuracy (0 to 2.5 mA): ±0.5% @ 25°C
Accuracy (2.5 mA to 50 mA): ±0.15% @ 25C
Load Resistor: 12 Ohms
Protection: ±100 mA
Temperature Sensor Type: Thermistor (Internal)
Measurement: 0°C to 70°C (32°F to 158°F)
Accuracy: ±0.2°C
Alarms Channel Alarms: (2) Editable Alarm Thresholds per Channel; Can be Configured as Alarm Outputs
Alarm Outputs: Alarm On (Switch On) and Alarm Off (Switch Off)
Alarm-On Delays: Programmable 0 to 10 Minutes Delay with 1 Minute Increments
Alarm Indicator: On-Board LED Lights in Red when in Alarm Condition
Data Storage Capacity 4 Million Readings
Data Retention Over 20 Years
Logging Mode Stop Recording or FIFO when Memory is Full
Start Mode Programmable Instant, Start Delay or Push-Button Activation
Sampling Rate 20 milliSeconds to 12 Hours (User Selectable))
Communications USB, AUX (RJ11) for Direct TTL Level Communications
Baud Rate: 2,400 to 115,200 (Auto-Detect) on both USB and AUX Ports
Power Source Built-in 3.6 Volt Lithium Battery
Battery Life 10 Years Based on 1 Minute Sampling Interval
Enclosure Constructed of Aluminum
LED Indicator Normal Sampling: Green When Sampling
Alarm: Red When Sampling
Low Battery: Amber When Sampling
Clock Accuracy ±1 Minute per Month
Excitation Control A2/EXT terminal strip can be Configured as Excitation Control Output for Powering Connected Devices
Warm-Up Delay Interval Settings: 10 to 240 seconds with 10-second Increments
Software Compatibility Windows 11, 10 and 7
Operating Environment Temperature: -40°C to 70°C (-40°F to 158°F)
Humidity: 0 to 95% RH Non-Condensing
Approvals CE, FCC
Mounting Probe/Wall Mount Holes for Hanging/Mounting
Weight 200 grams (7.05 oz.)
Dimensions 3.46" x 2.53" x 0.95" (88mm x 64.2mm x 24mm)
Customer Questions
No Questions
Please, mind that only logged in users can submit questions