LogTag CP100 Calibratable Smart Probe Kit

SKU
CP100K-15-KIT
In Stock
$79.00
  • -40°C to 90°C Measurement Range with 0.8°C Accuracy
  • Sensor Probe Can Be Swapped Out and Calibrated Separately
  • Gold-Plated MCX Connector for Secure Connection
  • 3 Year Battery Life
  • Compatible with the LogTag UTRED30-16 and UTRED30-WIFI Data Loggers

Kit Includes CP100K-15 Sensor, 60ml Glycol Bottle with Base. ISO Calibrated for Fridge and Freezer

The CP100K-15-KIT is a precise, swapable, temperature probe that comes pre-calibrated for use in both fridges or freezers.   Because the sensor itself is taking the temperature reading it eliminates the need to send in the actual logger when calibration becomes due.  When calibration is due, simply hot swap the existing standard or smart sensor with a newly calibrated smart sensor ensuring zero downtime.  These sensor kits include the sensor, glycol buffer bottle, mounting stand, and a calibration certificate.   The sensors are sold as stand-alone items so that they can be purchased as additional sensors to use to replace existing expired ones.  Additionally, these sensors can be purchased in various vaccine monitoring kits found elsewhere on our website.

The CP100K-15-KIT is compatible with the following loggers:

VAC-UTRED30-16 Logger & Kits

VAC-UTRED30-WIFI Loggers & Kits

LogTag CP100K-15-KIT Calibratable Smart Sensor Kit Specifications

Temperature Measurement Range: -40°C to 90°C (-40°F to 210°F)
Accuracy (-40°C to -20°C): ±0.5°C (±0.9°F)
Accuracy (-20°C to 40°C): ±0.8°C (±1.4°F)
Accuracy (40°C to 70°C): ±0.8°C (±1.4°F)
Accuracy (70°C to 99°C): ±1.2°C (±2.2°F)
Resolution (-40°C to 50°C): 0.1°C (0.2°F)
Resolution (50°C to 70°C): 0.2°C (0.4°F)
Resolution (70°C to 80°C): 0.3°C (0.5°F)
Resolution (80°C to 99°C): 0.4°C to 0.6C (0.7°F to 1.0°F)
Acquisition Interval Determined by Logger, Shortest Acquistion Interval 30 Seconds
Sensor Reaction Time Based on Tip, Same as for Current Probes
Operating Environment Temperature (Probe End): -40°C to 99°C (-40°F to 210°F)
Temperature (Signal Conditioning End): -20°C to 70°C (-4°F to 158°F)
Humidity: 0 to 100% RH (Non-Condensing)
Storage Environment Temperature: -40°C to 99°C (-40°F to 210°F)
Humidity: 0 to 100% RH (Non-Condensing)
Connection Interface 1-Wire Digital Interface to Compatible Data Loggers
Construction Signal Conditioning Case Material: Polycarbonate
Tip Material: Stainless Steel 316
Cable Material: PTFE
Environmental Probe Tip: IP68
Probe Tip/Cable Junction: IP64
Signal Conditioning: IP44
Compatibility UTRED30-WIFI Dual-Channel
UTRED30-16 Dual-Channel
UTRED30-16 Single-Channel
Weight 34 grams (1.2 oz.)