1000 Amp True AMS AC/DC Clamp Meter with NCV

SKU
R5040
Special Order
$179.00
  • Measures AC/DC Current and Voltage, Resistance, Frequency, Capacitance, Duty Cycle and Temperature
  • 50,000 Count Backlit LCD Display with a 61-Segment Analog Bargraph
  • Built-in Non-Contact Voltage (NCV) Detector
  • Constructed of Durable Double Molded Plastic Housing with CAT III 600 Volt Safety Rating

Includes Test Leads, Thermocouple Wire Probe, Thermocouple Adapter, (1) 9 Volt Battery and Soft Carrying Case

Special order - please allow 7-10 business days for this item to ship.
 
User Manuals and Product Guides

Reed Instruments R5040 1000A True RMS AC/DC Clamp Meter with NCV Specifications

AC/DC Current Measurement Range: 500 Amps, 1000 Amps
Accuracy (AC): ±(2.8% of Reading + 30 Digit
Accuracy (DC): ±(2.5% of Reading + 30 Digit
Resolution: 0.01, 0.1, 1 Amp
AC/DC Voltage Measurement Range (AC): 500mV, 5 Volts, 50 Volts, 500 Volts 750 Volts
Measurement Range (DC): 500mV, 5 Volts, 50 Volts, 500 Volts 1000 Volts
Accuracy (AC): ±(1.0% of Reading + 30 Digit)
Accuracy (DC): ±(0.1% of Reading + 4 Digit)
Resolution: 0.1mV, 0.001 Volts, 0.01 Volts, 0.1 Volts, 1 Volts
Resistance Measurement Range (AC): 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 50MΩ
Accuracy (AC): ±(1.0% of Reading + 4 Digit)
Resolution: 0.1Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ
Capacitance Measurement Range (AC): 500nF, 5000nF, 50µF, 500µF, 5mF
Accuracy (AC): ±(3.5% of Reading + 10 Digit)
Resolution: 0.01nF, 0.nF, 0.01µF, 0.1µF, 0.1mF
Frequency Measurement Range: 10kHz
Accuracy: ±(0.3% Reading + 2 Digits)
Resolution: 0.001Hz
Temperature Measurement Range: -100°C to 1000°C (-148°F to 1832°F)
Accuracy: ±(1.0% Reading + 2.5°C (4.5°F))
Resolution: 1.0°C (1.0°F)
Display 50,000 Count Backlit LCD
Features:Min, Max, Relative Mode, Diode Test, Auto Shut Off (After 15 Minutes), Range Selection (Autoranging/Manual), Display Hold
Features Duty Cycle, Non-Contact Voltage Detector, Low Battery Indicator
Jaw Opening 40 mm (1.5") up to 500 MCM
Analog Bargraph Yes (61-Segment)
Continuity Check Audible Signal if Resistance <35Ω
Power Supply (1) 9 Volt Battery
Operating Environment Temperature: 0°C to 50°C (32°F to 122°F)
Humidity: 10% to 80% RH
Storage Environment Temperature: -20°C to 60°C (-4°F to 140°F)
Humidity: 10% to 80% RH
Overvoltage Category CAT III 600 Volts
Standards Compliance CE
Weight 271 grams (9.6 oz.)
Dimensions 23.2cm x 7.7cm x 3.9cm (9.1 3.0" x 1.9")
Customer Questions
No Questions
Please, mind that only logged in users can submit questions