  1. SRP-008 SmartReader Plus 8 Temperature Data Logger
    01-0015
    • (7) External Thermistor Inputs and (1) Internal Temperature Sensor
    • Internal Temperature Sensor Features A Measurement Range of -40°C to 70°C (-40°F to 158°F) and ±0.2°C Accuracy
    • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
    • 25/second to 8 Hour User-Selectable Sampling Rate
    • Continuous (FIFO) or Stop When Full Sampling Methods
  2. SRP-001 SmartReader Plus 1 Temperature Data Logger
    01-0008
    • Internal Ambient Temperature Channel and External Thermistor Input
    • -40°C to 70°C (-40°F to 158°F) Temperature Measurement Range with 0.2°C Accuracy
    • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
    • 25/second to 8 Hour User-Selectable Sampling Rate
    • Continuous (FIFO) or Stop When Full Sampling Methods
  3. SRP-003 8 Channel AC Current, Voltage and Temp Data Logger
    01-0011
    • Measure & Record AC Current, Voltage and Temperature
    • 8 Channels: (1) Temperature and (7) 0 to 5 Volts DC Inputs
    • Temperature Measurement Range of -40°C to 70°C with a ±0.2°C Accuracy
    • 3 Memory and Data Storage Options Available (32 KB, 128K and 1.5MB)
    • 25/Second to 8 Hour User-Selectable Sampling Rate
    • 3.6 Volt Lithium Battery with 10 Year Life (Factory Replaceable)
  4. SRP-004 SmartReader Plus 4 Pressure and Temperature Data Logger
    01-0115
    • Measure and Record Pressure and Temperature and (2) Optional Inputs for Temp and RH
    • Self-Contained with 1/4" Quick-Release Pressure Fitting Connection
    • (7) Pressure Ranges Available with ±0.5% of Full Scale @ 25°C
    • 25/second to 8 Hour User-Selectable Sampling Rate
    • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
    • Continuous (FIFO) or Stop When Full Sampling Methods
  5. SRP-004 SmartReader Plus 4 Low Pressure Differential Data Logger
    01-0310
    • Measure and Record Low Differential Pressure and Temperature
    • (5) Pressure Ranges Available with ±0.5% of Full Scale @ 25°C
    • 25/second to 8 Hour User-Selectable Sampling Rate
    • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
    • Continuous (FIFO) or Stop When Full Sampling Methods
  6. SRP-005 SmartReader Plus 5 Thermocouple Data Logger
    01-0012
    • (2) External Thermocouple Inputs with Additional Internal Temp Sensor for CJC
    • Accepts Type J, K, S, T or E Thermocouple Sensor Probes
    • 25/second to 8 Hour User-Selectable Sampling Rate
    • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
    • Continuous (FIFO) or Stop When Full Sampling Methods
  7. SRP-006 SmartReader Plus 6 Thermocouple Data Logger
    01-0013
    • (7) External Thermocouple Inputs and (1) Internal Temperature Sensor
    • Accepts Type J, K, S, T or E Thermocouple Sensor Probes
    • Internal Temperature Sensor Features A Measurement Range of -40°C to 70°C (-40°F to 158°F) and ±0.2°C Accuracy
    • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
    • 25/Second to 8 Hour User-Selectable Sampling Rate
    • Continuous (FIFO) or Stop When Full Sampling Methods
  8. SRP-007 Smart Reader Plus 7 8-Channel Process Signal Data Logger
    01-0014
    • (1) Internal Temperature Sensor and (7) External Inputs for Process Signals
    • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
    • 25/Second to 8 Hour User-Selectable Sampling Rate
    • Continuous (FIFO) or Stop When Full Sampling Methods
    • Available in Multiple Voltage, Current or Voltage/Current Measurement Ranges